Hardware Installation Manual
38
Document #: LTRT-41749
Mediant 4000B SBC
5.1
Connecting the Ethernet Ports to the LAN
The cabling specifications and procedure for connecting the device to the LAN is as
follows:
Cable:
Straight-through, Category (Cat) 5, 5e or 6 cable
Connector:
Standard RJ-45
Connector Pinouts:
Table 5-1: RJ-45 Connector Pinouts
Pin
Name
Description
1
BI_DA+
Bi-directional pair A+
2
BI_DA-
Bi-directional pair A-
3
BI_DB+
Bi-directional pair B+
4
BI_DC+
Bi-directional pair C+
5
BI_DC-
Bi-directional pair C-
6
BI_DB-
Bi-directional pair B-
7
BI_DD+
Bi-directional pair D+
8
BI_DD-
Bi-directional pair D-
To connect to the LAN:
1.
Connect the RJ-45 port at one end of the cable to an Ethernet port on the SBC
module:
Figure 5-1: Connecting the LAN Interface
2.
Connect the other end of the cable to your LAN network.
Note:
For initial network connectivity to the device, use ports
GE 1
or
GE 2
to connect to
the LAN. These ports (or this Ethernet Group) are assigned to the OAMP interface
(192.168.0.2) by default. For port names as well as Ethernet port groups (for 1+1
redundancy), see Section
5.1.1
on page
39
.
Summary of Contents for Mediant 4000B SBC