Spacing of 1/4” to ducting within 3 feet of furnace must be provided 
unless UL listed wire bound vinyl ducts are used. All ducting 
material used to be rated for continuous use at minimum of 200°F. 

 

Clearances are specifically for plywood or similar building materials 
surrounding the furnace (i.e. Furnace should not be located under 
furniture or in a closet space where clothing or other material could 
be located). 

 

To install without adding the 36 sq. in. cutout on the blower side 
supply the unit (blower side) with 2” clearance full length of the unit.  

 

Furnace efficiency rating is a thermal rating determined under 
continuous operating conditions, independent of any installation. 
Efficiency rate is given at 76% minimum; actual efficiency rating 
may be higher. 

 

Return air is supplied through openings in furnace casing. All return 
air passages must be kept clear for furnace to function properly. 
Refer to Minimum clearance to floorboards, walls & similar 
combustible building material.  

 

The total unobstructed return air opening size(s) must not be less 
than specified in Table 1. Failure to meet minimum return air 
requirements nullifies furnace warranty. 

INSTALLATION AND SAFETY CODES 

USA and Canada – follow all applicable state and local codes – in the 
absence of local codes or regulations, refer to current standards of: 

 

Recreation Vehicles ANSI A119.2/NFPA 501C 

 

National Fuel Gas Code ANSI Z223.1 and/or CAN/CGA B149  

Installation Codes 

 

This furnace must be installed in accordance with the 
manufacturer’s instructions and the manufactured Home 
Construction and Safety Standard, Title 24 CFR, part 3280, or when 
such standard is not applicable, the Standard for Manufactured 
Home Installations. (Manufactured Home Sites, Communities and 
Set-Ups), ANSI A255.1 and/or CAN/CSA-Z240 MH Series M92 
Canadian Standard for Mobile Homes.” 

 

ANSI A 255.1 and/or CAN/CSA-Z240.6.2 MH Series, Mobile Homes 

 

Ground National Electrical Code ANSI/NFPA 70 and/or CSA C22.1, 
Part 1 

 

Park Trailers ANSI 119.5 

 

GENERAL FURNACE LOCATION AND INSTALLATIONS 

 

 

All models can be installed in either a horizontal or vertical mounting 
position horizontal installed units have the gas line positioned on top 
or rear, vertical installed units have the vent located at floor level 
and gas line at right side and rear. 

 

Always install furnace through an exterior wall. 

 

DO NOT install furnace near tilt-out rooms, slide-outs, doors or 
other projection that could obstruct furnace exhaust. 

 

Locate furnace near midpoint of coach for single furnace 
applications. 

 

Installation must provide accessibility if any repairs are necessary to 
the furnace. Failure to meet this requirement will create additional 
labor costs that will be the responsibility of the installer. 

 

DO NOT install vent in areas where projection or door openings 
come within 6” of vent opening. 

 

DO NOT install furnace in an area where wires, pipes or other 
objects will interfere with installation or operation of furnace. 

 

DO NOT install furnace on material that restricts return air, such as 
directly on carpet, or soft material (like vinyl). If you must install 
furnace on carpet or soft material, install furnace on cleats, or on a 
wood or metal panel extending the full width and depth of furnace 
plus minimum clearance to combustibles. 

 

DO NOT use petroleum or citrus type cleaner on plastic parts, as 
damage may occur. 

 

CAUTION: Due to the differences in vinyl siding materials this 
appliance should not be installed without first consulting with the 
manufacturer of siding. 

 

 A gas-fired furnace for installation in a residential garage must be 
installed so the burner(s) and the ignition source are located not 
less than 18 in (457mm) above the floor and the furnace must be 
located or protected to avoid physical damage by vehicles. 

 
 
 
FURNACE INSTALLATION 

 

The furnace should always be installed level (front to back, side to 
side) to prevent water intrusion into the interior. 

 

Set aside venting and outer door parts for installing on the outside 
of coach. 

 

NOTE to assure sufficient return air to circulating blower maintain 
specified clearances see table 4. 

 

If units are installed using the small outside vent system access to 
the inside of the coach must be provided directly in front of the unit 
to remove for service suggested opening size 17” wide by 8-3/8” 
height. 

 

Remove knockouts from furnace and install duct adapters for side 
discharge by inserting back flange over casing and inserting tab into 
square notch, then twist adapter 90°. 

 

Insert furnace into cabinet opening and secure with two screws 
through casing legs to floor. Units are secured by means of door or 
vent systems through the coach sidewall with casing legs at the 
rear. 

 

Attach flexible ducting over duct adapters and secure. All flex 
ducting requires rating of 200°F. 

 

Run ducting to locations keeping bends and excess ducting to a 
minimum and secure to registers. 

 

Connect wiring to located on the top of the furnace.  See wiring 
connection section. 

 

Connect gas line to top or rear of furnace.  See gas connection 
section. 

 
1. 

Cut the required exterior wall opening for your venting system see 
Figure 1. 

2. 

Configure furnace for ducting option to be used refer to duct 
configurations table 2. 

3. 

Install furnace into opening and attach ducting to adapters. 

4. 

Make gas and electrical connections, which are located on the top 
of the unit. 

5. 

See door or vent installation instruction below on how to complete 
the venting system.  

 

SIDEWALL CUTOUT  

Recommended exterior wall thickness 0” to 2-1/2”. 

Small vent system 0” to 2-1/4”. 

 

WALL CUTOUTS Table  

 

Side Wall Cutout Small Vent Max 

Wall Thickness 2-1/2” 

3-1/4” Dia. 

Side Wall Cutout Standard Door 

(horizontal or vertical) 

17” MAX 

7-1/2” 

MAX 

 

Side Wall Cutout Flush Door 

(corner cut requires 3/4” radius) 

(horizontal or vertical) 

18-3/4” 

MAX 

9-3/8” 

MAX 

 

     

 

Figure 1 

DO NOT oversize hole – over sizing can result in water leakage. 
Zero clearance around air intake cutout for best sealing condition. 
 

 

Summary of Contents for AFMD16

Page 1: ... cabinet area as a storage compartment DO NOT vent furnace with venting system serving another appliance DO NOT vent furnace to an outside enclosed porch area DO NOT use for temporary heating of buildings or structures under construction Protect building materials from degrading from flue gas exhaust Protect furnace electrical components from water Compartment must be closed when operating unit Sh...

Page 2: ...1 AFMD20111 AFMD20121 AFMD25111 AFMD25121 AFMD30111 AFMD30121 AFMD35111 AFMD35121 Type of Gas LP Propane LP Propane LP Propane LP Propane LP Propane BTU Input 16 000 20 000 25 000 30 000 34 000 BTU Output 12 160 15 200 19 000 22 800 25 840 Duct Static Pressure 20 WC 10 WC 10 WC 10 WC 10 WC Amperage AMPS 4 2 4 2 7 5 7 5 11 1 Watts 50 50 90 90 132 Power Supply Volt DC 12 12 12 12 12 Return Air 80 in...

Page 3: ...ere wires pipes or other objects will interfere with installation or operation of furnace DO NOT install furnace on material that restricts return air such as directly on carpet or soft material like vinyl If you must install furnace on carpet or soft material install furnace on cleats or on a wood or metal panel extending the full width and depth of furnace plus minimum clearance to combustibles ...

Page 4: ...ezel creating a sealing area 3 Pull furnace forward through cutout about a 1 inch slip bezel around casing and flush inner flange with casing 4 Secure bezel to furnace casing with 6 screws 5 Push furnace and bezel back tight against side wall and secure with 14 screws 6 When installing screws DO NOT deform bezel 7 Connect the gas line to the valve and push the gas line plug into casing opening 8 R...

Page 5: ... needed to maintain installation duct air flow requirements DO NOT install floor registers within 2 feet of return air openings See ducting option from casing top and bottom areas These options can be with flex ducting or by hard ducting installations Hard ducting must be sealed to insure proper operation of the appliance HORIZONTAL OR VERTICAL BOTTOM DISCHARGE Figure 6 Units can be installed as b...

Page 6: ...or servicing Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Disconnect electrical power before servicing CAUTION PROPERTY DAMAGE This connection is for low voltage battery or direct current only Do not connect to 120 or 240 volts AC POWER SUPPLY Atwood Mobile Products highly recommends the use of an electronic solid state converter with clean power...

Page 7: ...come on 6 Allow 30 seconds for main burner to light after blower comes on This furnace is equipped with an ignition device which automatically lights the burner DO NOT try to light the burner by hand 7 If burner does not light repeat Steps 1 through 5 8 If after three 3 attempts with no ignition go to shut down and contact your dealer or a local recreational vehicle service agency Do not continue ...

Page 8: ...8 WIRING AND LADDER DIAGRAM ...

Page 9: ...9 PART DRAWINGS PART LISTS ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...nt de rangement NE PAS aérer la fournaise avec un système de ventilation pour entretenir un autre appareil NE PAS aérer la fournaise à un endroit extérieur fermé comme une véranda NE PAS utiliser pour le chauffage temporaire de bâtiments ou de structures en construction Protégez les matériaux de construction contre la détérioration par l échappement de gaz à combustion Protégez les composantes éle...

Page 13: ...RTE 15 INSTALLATION DE LA PORTE PLANE 16 OPTIONS DE TUYAUTERIE 16 SYSTÈMES DE TUYAUTERIE FLEXIBLE 16 SYSTÈMES DE CONDUITS SOLIDES POUR LE PLANCHER 16 DÉCHARGE PAR LE BAS HORIZONTALE OU VERTICALE 17 PLAQUE D ADAPTATEUR FLEXIBLE 17 CONNEXION DE GAZ PROPANE 17 CONNEXIONS ÉLECTRIQUES 18 INSTALLATION DU THERMOSTAT 18 INSTRUCTIONS D UTILISATION 18 POUR METTRE HORS TENSION 19 SPÉCIFICATIONS MODÈLES Table...

Page 14: ...roite Toujours installer la fournaise sur un mur avec paroi extérieure NE PAS installer la fournaise près d une chambre à bascule de murs coulissants de portes ou autres projections qui pourraient compromettre l échappement de la fournaise Placez la fournaise vers le milieu du guide pour l installation d une seule fournaise L installation doit être accessible si une réparation est nécessaire pour ...

Page 15: ...sion d air de combustion Fixez au mur avec deux vis non fournies 15 L assemblage du conduit doit maintenir un chevauchement minimum de 1 1 4 po sur le tube d échappement et un minimum de 1 2 po du tube de combustion d air NE PAS excéder l épaisseur du mur 16 Fixez la fournaise au plancher avec deux vis à travers les pieds à l arrière du boitier Pour les appareils à la verticale maintenez la fourna...

Page 16: ...omplètement scellé 11 Fixez le pied de montage au plancher pour une installation horizontale Pour les unités verticales retirez les vis des pieds du boitier et repositionnez le pied pour une surface de montage verticale pour maintenir la fournaise en position 12 Fixez la porte et le conduit avec les 6 vis fournies bonne pression statique OPTIONS DE TUYAUTERIE DÉCHARGE MINIMUM REQUISE Modèles Zone ...

Page 17: ...hez les conduits flexibles de la fournaise à la plaque d adaptateur flexible et fixez le conduit en place sur les deux côtés 8 Des conduits additionnels peuvent être utilisés pour maintenir une bonne pression statique ou telle que désirée VÉRIFICATION DU FLUX D AIR Les appareils sont testés pour une augmentation de la température telle que spécifiée dans le plateau de classement Lorsque l installa...

Page 18: ...de la fournaise 2 Connectez le câble rouge au côté positif du bloc d alimentation 3 Connectez le câble noir à la mise à la terre du bloc d alimentation 4 Connectez le fil bleu marqué positif du thermostat au côté du fil du thermostat en utilisant un fil toronné de 22 18 GA 5 Connectez l autre fil bleu à la tête du thermostat en utilisant un fil toronné d un minimum de 22 18 GA ALIMENTATION ÉLECTRI...

Page 19: ...ve de fermeture automatique individuelle doivent être déconnectées du système de tuyau vers l approvisionnement en gaz durant le test de la pression du système aux tests de pression de plus de 1 2 po PSI Avant de connecter la fournaise le système de tuyaux doit être testé pour les fuites Le test doit maintenir la pression d air à au moins 6 po de mercure ou 3 PSI durant au moins 10 minutes Le syst...

Reviews: