38
EN
7.10
DISASSEMBLY OF THE REGULATOR
If it is necessary to disassemble the regulator, do the following:
•
turn the main switch off
•
disconnect the boiler from electricity mains
•
demount the regulator
•
demount the connectors from the regulator
7.11
TECHNICAL SPECIFICATION OF THE REGULATOR
Power
supply
230
V
±
10 %, 50 Hz
Input (not including the ventilator and pumps)
< 4 VA
Range of measuring the boiler temperature
−9 – 109 °C
±
1 °C
Range of measuring the flue gas temperature
−30 – 500 °C
±
1 °C
Max. input of devices connected to the regulator
2 A/230 V
7.12
OUTPUT CONTROL OF ATTACK DPX COMBI PELLET
Adjustment of burning in the boiler
The burning is adjusted by the primary and secondary
regulation flap. Producer sets the boilers to the opti-
mum conditions of burning with reference to the emis-
sions and flue gas temperature. Only the service staff
trained by producer can make the adjustment.
Optimum setting of the regulation flaps – wood
mode (Primary/Secondary):
DPX25CP – 50/40
DPX30CP – 50/25
DPX35CP – 50/50
DPX40CP – 100/60
DPX45CP – 100/60
7.13
OPERATION WITH PERMANENT BURNING
It is possible to keep the permanent burning, i.e. the fire in the boiler for the whole night without
need to heat up during the day, but only in the winter period. This method of operation reduces
the life of the boiler.
For the operation with permanent burning it is necessary to prepare the boiler in the fol-
lowing way:
•
Lay some bigger wood logs (4 – 6 pcs.) on a glowing layer of fuel
•
Close the mixing valve partly – temperature of water in the boiler achieves 80 – 90 °C
•
The regulation flap controlled by thermal regulator is automatically closed and the fan is
stopped.
After the boiler is prepared in this way, the burning is kept for more than 12 hours. When
the boiler is in the operation of permanent burning, the water temperature must be
80 – 90 °C.
Summary of Contents for ATTACK DPX 25 COMBI Pellet
Page 1: ...www attack sk EN 07 2019 ATTACK DPX COMBI PELET Instructions for use EN ...
Page 2: ......
Page 66: ...65 EN 13 ELECTRICAL SCHEMES 13 1 ATTACK DPX 25 30 35 COMBI PELLET ...
Page 68: ...67 EN 13 2 ATTACK DPX 40 45 50 COMBI PELLET ...
Page 83: ...11 ...
Page 98: ......
Page 99: ......