39
EN
8
BURNER ASSEMBLY TO THE BOILER
The boiler DPX COMBI Pellet – mode wood has mounted on the upper loading door cover – cov-
er of the upper loading door. If you want to go for automatic pellet combustion, you have to
remove this plug by simply movement up and down with the two handles and put it away from
the boiler. After that it is necessary to mounted the pantograph, burner door and burner on the
boiler.
Steps of burner assembly to the boiler:
1.
For simple manipulation and operation during operation of the burner, the burner together
with the burner door will be placed on the movable arms of pantograph. For their installa-
tion is necessary to mount the pantograph console in the hole in the right leg of boiler. Con-
sole will be fixed with four screws M12 × 20 with cylindric head and internal hexagonal
screwdriver.
2.
Then it is easy to put together arms of pantograph by pins, cotter and mats. By mounting the
short arm of the pantograph is required to put bronze mat between the bottom of arm and
Summary of Contents for ATTACK DPX 25 COMBI Pellet