51
EN
9.6.2
ATTACK PELLET BURNER AUTOMATIC 15–50 KW
Basic menu:
Menu
Settings
Range
Adjustable
Effect level
3 = 50 kW
1, 2, 3
15 – 50 kW
Pellet–trim
95 %
50 – 200 %
50 – 200 %
Final combustion
Yes
Yes/No
10 – 600 s
Log View
faults N/Y
N/Y
Advanced menu
View random number
Entry code + 5
N/Y
Advanced menu
MENU
Parameter
Range
Adjustable
Effect adj.
Output 1 [kW]
15 – 50
15
Output 2 [kW]
15 – 50
32
Output 3 [kW]
15 – 50
50
Ignition
Delay 0
–
3
1
Feeding time 1
30 – 500 %
200 %
Ignition time 1
10 – 600 s
500 s
Feeding time 2
10 – 300 %
100 %
Ignition time 2
10 – 600 s
240 s
Fan speed
800 – 2 800
800
Test–blow time
Delay
10 – 100 s
15
Transition phase
Transition phase time 0 – 14
20 – 460 s
240
Transition phase time 0 – 30
260 – 800 s
480
Transition pellet–trim Transition phase trim
10 –100 %
15 %
Clean–blow time
Clean–blow time
10 – 900 s
200
Max. comb. time
Max. comb. time
30 – 1 080 min
60 min
Anti–cycling Anti–cycling
0 – 60 min
10
Modulation
Power modulation
0 – 100 %
70
Temperature modulation
range
1 – 100 deg
10
Photocell
Photocell
25 – 80 %
30
Thermostat Thermostat
EXT; SENS; COMBI
COMBI
Temperature of switch–off
15 – 99
80°C
Hysteresis 1
–
75
10°C
Cleaning
Activate?
Yes/No
Yes
Grate cleaning?
Before ig., Before ig./after
burn–out
Before ig./after burn–
out
Delay?
0 – 60 min
1
Number of cleaning
1 – 5
1
Pump control
Pump active?
Inactiv/Automatic
Automatic
Delay
0 – 60
10
Language
Language
EN, SK, CZ, HU, ES, …
EN
Socker adj.
Heat amount
45 – 60 kWh/kg 50
Fan factor
Fan
10 – 500
100
Fan 1 Gain
0 – 100
10
Fan 1 Interval
0 – 50
1
*) Languages: Slovak, Czech, English, German, Greek, Hungarian, Italian, Polish, French, Spanish
Summary of Contents for ATTACK DPX 25 COMBI Pellet