EN
console, as well the mat on the bottom part of console. Pin is necessary to secure with the
cotter.
3.
The same process is applyed by installation of the long arm of the pantograph, where we put
the bronze mat between short and long arm of pantograph, mat on the bottom part of short
arm and pin is secured by cotter.
4.
Burner door are supplied with console and pin, in one piece, for simple installation to the
arm of the pantograph. Between the console door with pin and long pantograph arm put
again bronze mat, other mat under the bottom part of the long arm and pin is secured by
cotter.
5.
Secure the burner door on movable arm to upper door of the boiler by simple movement of
two handles. It is the same how it was by demounting of the plug.
6.
Burner with flange pushed onto the welded screws on the burner door and secure with flat
mat 8,4 and nuts M8.
7.
Hanging cable for burner connection to the boiler to attach as well as the boiler temperature
sensor to the arm of the pantograph by supplied plastic tapes from the bottom of the pan-
tograph arms. Then put the cover on the burner.
9
OPERATION OF BOILER ATTACK DPX COMBI PELLET –
PELLETS MODE
Pellet burners ATTACK PELLET BURNER Automatic 8 – 30 kW and 15 – 50 kW built into the boiler,
model ATTACK DPX COMBI Pellet 25, 30, 35, 40, 45, 50 are modern burners which are saving en-
vironment with combustion technology, offer to end users the advantage of low operating costs
and offer also comfort comparable with the gas boilers when is boiler operating with pellets,
automatic combustion.
For the boiler operation with pellets is necessary to remove the plug of upper loading door.
Block off two handles and put the plug away from the boiler. With the pantograph simply bring
burner to the upper door of the boiler, insert it through the door into the boiler and block the
burner with two handles. By blocking the burner to the door of the boiler, needs to make pres-
sure in a straight line. The burner door needs to seal with the boiler door.
Inserting and securing the burner in the boiler door, burner is ready for operation. On the con-
trol panel you must switch the mode switch to PELLETS position.
At the time when the burner is out of the boiler door it is not possible to operate or change the
settings in the menu.
Summary of Contents for ATTACK DPX 25 COMBI Pellet
Page 1: ...www attack sk EN 07 2019 ATTACK DPX COMBI PELET Instructions for use EN ...
Page 2: ......
Page 66: ...65 EN 13 ELECTRICAL SCHEMES 13 1 ATTACK DPX 25 30 35 COMBI PELLET ...
Page 68: ...67 EN 13 2 ATTACK DPX 40 45 50 COMBI PELLET ...
Page 83: ...11 ...
Page 98: ......
Page 99: ......