Time setting of the cleaning by blow–through:
The cleaning by blow–through is activated, when the thermostat
switches off and the value recorded by the photocell decreases
under 12 %.
Setting of the maximum burning time:
By this parameter it is possible to set the maximum time of the
continuous burner operation.
Setting of the minimum duration of the break between the burn–down and the ignition:
This parameter ensures, that it comes to the next burner ignition
only after the stated time, not immediately after the burn–down.
Setting of the time of the blow–through clening:
By the stated value of
¨
T, before achieving the required boiler
temperature, the boiler output decreases automatically to the
pre–set level.
Setting of the photocell sensibility:
Here you can set the photocell sensibility, i.e. the value of light in
(%), to which should the system react as to the fire. It should not
be necessary to set the light sensibility, if the correct photocell is
installed. The setting from production is: 50%.
Selection of the thermostat:
Here you select the required thermostat: the external boiler
thermostat or the burner thermal probe, or combination with the
room thermostat.
If you use the burner thermal probe, it is possible to set 2 parameters. Firstly, select the
starting
temperature,
save the value by pressing the „S“ button, then you can change the
stop tempera-
ture.
By repeated pressing of „S“ you save this value as well. The burner will now work in the
range of the actually set temperature values. There should be difference between the starting
and the stop temperature of at least 5 °C.
Grate cleaning:
By this parameter you can set, if the grate cleaning will be acti-
vated and when it has to be turned on – before the ignition or
after the burn–down.
Pump control:
By this parameter you can set if the pump will be controlled and
if yes, then how long the delay will be.
Pump safety tem–perature:
By overloading this temperature there will be turned on
pump.
CLEANBLOW TIME
ENTER
< > EXIT
COMBUST. TIME
ENTER
< > EXIT
MIN. PAUSE TIME
ENTER
< > EXIT
MODULATION.
ENTER
< > EXIT
PHOTOSENSOR
ENTER
< > EXIT
THERMOSTAT
ENTER
< > EXIT
SCRAPER
ENTER
< > EXIT
Pump Control
ENTER
< > EXIT
Pump safety temperature
ENTER
< >
EXIT
Summary of Contents for ATTACK DPX 25 COMBI Pellet
Page 1: ...www attack sk EN 07 2019 ATTACK DPX COMBI PELET Instructions for use EN ...
Page 2: ......
Page 66: ...65 EN 13 ELECTRICAL SCHEMES 13 1 ATTACK DPX 25 30 35 COMBI PELLET ...
Page 68: ...67 EN 13 2 ATTACK DPX 40 45 50 COMBI PELLET ...
Page 83: ...11 ...
Page 98: ......
Page 99: ......