17
1.
Make sure the supervising computer (Modbus Master)
is connected to your target switch
(Modbus Slave).
2.
Launch
Modbus Poll
in the supervising computer.
3.
Click connect button on the top toolbar to enter Connection Setup.
Figure 2.23 Modbus Poll entries Connection Setup
4.
Select
Modbus TCP/IP
as the connection mode and enter the switch’s IP address inside the
Remote Server IP Address field. The Port number is 502.
Figure 2.24 Modbus Poll Connection Setup
5.
Modbus Poll Slave ID should match Figure 2.21.