- 18 -
Following LEDs are used on the
Qc1002™
Qc1002™ Menu Overview
At Qc1002™, the LCD will show following
information:
– in
Normal
condition (scroll through the
information using
UP
and
DOWN
):
• Status (eg: preheat, crank, run, cooldown,
extended stop time, …)
• Controller type & version
• Parameter list
• Alarm list
• LOG list
• Service Timer 1 & Service Timer 2
• Battery Voltage
• Coolant temperature
• Oil pressure
• RPM (speed)
• Fuel level
• Voltage - frequency - running hours
– in
Alarm
condition (scroll through the
information using
UP
and
DOWN
):
• a list of all active Alarms
It's possible to scroll through the views, using the
UP
and
DOWN
buttons. The scrolling is continuous.
If a Special status comes up, the Status Display is
shown.
If an Alarm comes up, the Alarm Display is shown.
START:
Is used to start the unit in
Manual Mode.
STOP:
Is used to stop the unit in
Manual or Remote Mode (always
with shutdown!). When the unit is
stopped with the STOP button in
Remote mode, it will automatically
go to Manual Mode.
Power
Green LED indicates that the unit is
powered up.
Remote
Green LED indicates that the Remote
Mode is selected.
Start/Stop
Green LED indicates that the engine
is running.
Alarm
Flashing red LED indicates that an
alarm is present. A continuous red
LED indicates that the alarm has been
acknowledged by the user. The exact
alarm is shown on the display.
Remote
Power
Alarm
Start/Stop
Qc1002 CAN
145
Summary of Contents for QAS 275-325
Page 1: ...QAS 275 325 Volvo S2A APP Instruction Manual for AC Generators English...
Page 2: ......
Page 91: ...91 Circuit diagrams...
Page 95: ...95...
Page 99: ...99...
Page 103: ...103...
Page 107: ...107...
Page 112: ...112...
Page 113: ......
Page 114: ...Printed in Belgium 11 2010 2954 3880 01 www atlascopco com...