5.2
Before starting
Warning
Step
Action
The operator must apply all relevant safety precautions. See the section
Safety
precautions
.
Switch off your mobile phone when in the vicinity of a GA VSD compressor which is under
tension.
Procedure
Step
Action
-
Switch on the voltage. The voltage-on LED lights up.
-
Close condensate drain valves.
-
Open the air outlet valve.
-
Check the oil level. The pointer of the oil level gauge should be in the green range or orange
range.
If the compressor has only just stopped, wait one minute before checking the level.
5.3
Starting
Procedure
Step
Action
•
When the compressor is stopped and the automatic operation LED (3) is lit, the
compressor may start automatically.
•
If the start/stop timer is active, the compressor may start automatically, even if it was
stopped manually. See the section
Control panel
Instruction book
78
APF192090