3.5
Emergency stop button
Control panel
Description
In case of emergency, press button (S2) to stop the compressor immediately.
Using the emergency stop breaks the circuit to:
• the variable speed drive unit of the drive motor.
• on air-cooled compressors, the variable speed drive unit of the fan motors.
•
• on GA (W) VSD Full-Feature compressors, the variable speed drive unit of the compressor motor of the
dryer.
By using the emergency stop, solenoid valve (Y2) will open the blow-off port, resulting in depressurisation
of the air receiver.
At the occurrence of an emergency stop, the compressor element is stopped immediately and the solenoid
valve will be deactivated by Elektronikon ® regulator. No unload status is reached. The check valve prevents
oil flow back from reversed rotation of the compressor element.
Before starting any maintenance or repairs, wait until the compressor has
stopped and open the isolating switch (customer's installation) to switch off the
voltage to the compressor.
Close the air outlet valve and open the manual condensate drain valves to
depressurize the air system.
Apply all relevant
3.6
Control programs
Function
In order to facilitate programming and controlling, menu-driven control programs have been implemented in
the regulator.
Instruction book
22
APF192090
Summary of Contents for GA 160 VSD
Page 1: ...GA 160 VSD APF192090 Instruction book ...
Page 2: ......
Page 64: ...Instruction book 62 APF192090 ...
Page 66: ...Figure A Instruction book 64 APF192090 ...
Page 67: ...Figure B Instruction book APF192090 65 ...
Page 70: ...Text on figure Instruction book 68 APF192090 ...
Page 77: ...Ref Designation 29 Do not mix oil brands Instruction book APF192090 75 ...
Page 92: ...See Oil specifications Instruction book 90 APF192090 ...
Page 111: ......