Minimum
setting
Factory
setting
Maximum
setting
Proportional band
%
10
15
20
Integration time
sec
1
10
20
Minimum motor speed
rpm
600
600
1500
Maximum rpm reduction
%
75
100
100
Parameters
Minimum
setting
Factory
setting
Maximum
setting
Minimum stop time:
sec
0
15
255
Permissive start time:
sec
0
30
255
Power recovery time (ARAVF)
sec
15
15
3600
Restart delay
sec
0
3
255
Communication time-out
sec
10
20
60
Protections
Minimum
setting
Factory
setting
Maximum
setting
Compressor outlet temperature:
Shut-down warning level
˚C
20
66
80
Shut-down level
˚C
20
80
80
Compressor element outlet temperature:
Shut-down warning level
˚C
80
114
120
Shut-down level
˚C
80
120
120
Cooling medium temperature:
Air-cooled compressors (shut-down warning
level)
˚C
0
50
55
Air-cooled compressors (shut-down level)
˚C
0
55
55
Delay at signal
sec
0
20
60
Ambient temperature:
Shut-down warning level
˚C
0
50
55
Shut-down level
˚C
0
55
55
Delay at signal
sec
0
255
255
Oil separator temperature:
Shut-down warning level
˚C
0
120
120
Shut-down level
˚C
0
120
120
Delay at signal
sec
0
1
3
dp oil separator (shut-down warning level)
mbar
--
850
1000
dp oil separator (shut-down level)
mbar
--
1000
1000
Instruction book
46
APF192090
Summary of Contents for GA 160 VSD
Page 1: ...GA 160 VSD APF192090 Instruction book ...
Page 2: ......
Page 64: ...Instruction book 62 APF192090 ...
Page 66: ...Figure A Instruction book 64 APF192090 ...
Page 67: ...Figure B Instruction book APF192090 65 ...
Page 70: ...Text on figure Instruction book 68 APF192090 ...
Page 77: ...Ref Designation 29 Do not mix oil brands Instruction book APF192090 75 ...
Page 92: ...See Oil specifications Instruction book 90 APF192090 ...
Page 111: ......