• Use the scroll keys (1) to change the setting.
• Press ”Program” (F1) to program the new value or “Cancel” (F3) to cancel the modification operation.
• The screen (see example below) shows a horizontal arrow indicating that the shut-down warning value
can be modified (the procedure is similar to the description above).
• The procedure to modify other items is similar. For some settings, a delay can be programmed.
Example of the screen for GA compressors
“Element Outlet”
94˚C
“Shutdown”
“Maximum”
110˚C
“Menu”
“Modify”
F1
F2
F3
The regulator will not accept new values beyond the limits. Press the key “Limits” to check
the limits for the parameter. Consult
Programmable settings
for the most important settings.
3.18 Modifying service plans
Function
To modify the hour intervals for the service levels.
Service plans
The service actions to be carried out are grouped in plans called Service level A, B, C or D. When reaching
an interval, a message will appear on the screen indicating which Service plans are to be carried out.
Always consult your Atlas Copco Customer Centre in case any timer should be changed. The
intervals must not exceed the programmed nominal values.
Instruction book
36
APF192090
Summary of Contents for GA 160 VSD
Page 1: ...GA 160 VSD APF192090 Instruction book ...
Page 2: ......
Page 64: ...Instruction book 62 APF192090 ...
Page 66: ...Figure A Instruction book 64 APF192090 ...
Page 67: ...Figure B Instruction book APF192090 65 ...
Page 70: ...Text on figure Instruction book 68 APF192090 ...
Page 77: ...Ref Designation 29 Do not mix oil brands Instruction book APF192090 75 ...
Page 92: ...See Oil specifications Instruction book 90 APF192090 ...
Page 111: ......