background image

9

PREVENTIVE

 MAINTENANCE

  

AND

 INSPEC

TION

3

•  Carefully inspect pull pins, snap locks, weight stack 

selector pins and all pivoting connecting parts. Replace 
at first sign of wear.

•  Inspect cables thoroughly over their entire length and 

at each insertion point and replace immediately if 
damaged. When changing a cable, note the replacement 
date for your records (see 

(4) Replacing Parts section in 

this manual).

•  Inspect cables thoroughly over their entire length and 

at each insertion point and replace immediately if 
damaged. When 

changing a cable

, note the replacement 

date for your records (see 

(4) Replacing Parts section in 

this manual).

•  Inspect belts thoroughly over their entire length 

and at each insertion point. If a belt shows signs of 
delaminating, cracking or wear that has reduced its 
original width or thickness, it should be replaced 
immediately. All insertion point hardware should also be 
carefully inspected for signs of wear. When changing a 
belt, note the replacement date for your records (see 

(4) 

Replacing Parts section in this manual).

Maintenance and inspection schedule: 

Weekly maintenance

ASSEMBLY WITH ACCESSORY HOOK

ALLEN KEY 5/32

ALLEN KEY 7/32

KEY 9/16

ALLEN KEY 5/32

Summary of Contents for P140

Page 1: ...1 FEEL THE STRENGTH OWNER S MANUAL 2020...

Page 2: ...on regarding the operation and maintenance of your Atlantis equipment so that your members enjoy years of safe and exhilarating strength training pleasure USING THIS MANUAL All Atlantis units can be i...

Page 3: ...and washer s combinations in the same order they were removed Atlantis strongly recommends at least two people perform the following procedures for safety and comfort WARNING Please note that shippin...

Page 4: ...der to do so tighten the bolts by hand before using a ratchet or impact driver Weight stack units are typically shipped fully assembled apart from their weight stacks which are packed in boxes It is i...

Page 5: ...her between the cylindrical bolt and the flat washer On other stations you will find regular nut and bolt assemblies that do not require these washers Carefully let the guide rods lean to whichever si...

Page 6: ...up the guide rod and twist it into the stored position on the cylindrical bolt 9 Put the weight sticker on each plate as per diagram NOTE Fronts of plates should be wiped with rubbing alcohol before...

Page 7: ...tlantis equipment Use each unit for its intended exercise s only Do not modify a unit in any way Ensure that all users obtain a medical exam and receive proper instructions before using Atlantis equip...

Page 8: ...nspection Clean upholstery with any upholstery safe sanitizing spray using a soft damp cloth clean sweat free upholstery lasts up to 40 longer For especially persistent stains apply rubbing alcohol li...

Page 9: ...lace immediately if damaged When changing a cable note the replacement date for your records see 4 Replacing Parts section in this manual Inspect belts thoroughly over their entire length and at each...

Page 10: ...ght stack guide rods should be clean and have a light layer of lubricant on them for optimal performance Failing to wipe guide rods clean first will lead to unwanted resistance and premature wear on b...

Page 11: ...y assembly see figures below The cable will tighten as the screw goes down Clean frames and inside of weight stack shrouds with a solution of Simple Green All Purpose Cleaner an environmentally friend...

Page 12: ...isstrength com or from 8 30 am 4 30 pm Eastern Standard Time UTC 5 at 1 877 454 2285 ext 239 To order TFL 50 in the United States or internationally contact TFL International from 8 am 4 pm Eastern St...

Page 13: ...ommended for units with a weight stack over 200 lb 91 kg If unsure of the cable size to use please contact a customer service representative NOTE The A201 and A301 are the only machines that use a Kev...

Page 14: ...d Threadlocker Please contact our service department with the following information relating to the unit such as model number serial number pictures and location of pad s on the unit so that we may be...

Page 15: ...adjusting heavy parts If the pre stretch pedal does not return to starting position automatically the shock has lost its resistance If faced with this situation begin by lubricating the shaft and NOT...

Page 16: ...by Atlantis for 1 year following the delivery date provided that the equipment is located within Atlantis or its distributors service zones Please refer to your sales invoice for any specifications r...

Page 17: ...repair or replace the component within the terms stated above Atlantis shall not be liable for any loss or damage of any kind including any incidental or consequential damages resulting directly or i...

Page 18: ...ge that is not apparent and discovered after delivery of the equipment must be brought to the attention of Atlantis both verbally and written within 14 days of delivery Any delays in making such a cla...

Page 19: ...ON 7 Contact information Atlantis Inc 4745 avenue des Industries Laval Qu bec Canada H7C 1A1 Tel 450 664 2285 Fax 450 664 4900 Toll free 1 877 454 2285 Website www atlantisstrength com Email service a...

Reviews: