Fault code
Following fault codes can be indicated in the display 2 “Relative humidity of air”:
Fault code
Fault
E3
Humidity sensor defective.
E4
Water collecting container full.
E5
Refrigeration circuit sensor defective.
L
Please contact the manufacturer or customer service of the fault codes E3 or E5 appear.
T
T
e
e
c
c
h
h
n
n
i
i
c
c
a
a
l
l
s
s
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
Type
HT 600
HT 800
Model
ALE 600
ALE 800
Air flow rate
680 m³/h
680 m³/h
Rated power
1000 W
1200 W
Rated current consumption
4.6 A
5.3 A
Max. power
1200 W
1410 W
Max. current consumption
5.4 A
6.4 A
Power, fan
50 W
50 W
Electrical power supply
230 V~ / 50 Hz
230 V~ / 50 Hz
Power system fuse protection
10 A
10 A
Temperature range
5 – 32 °C
5 – 32 °C
Humidity of air range
30 – 90% rel. humidity of air
30 – 90% rel. humidity of air
Dehumidification performance at 30 °C / 80% RH
60 l / 24 h
80 l / 24 h
Degree of protection
IP X0
IP X0
Freezing pressure
2.5 MPa
2.5 MPa
Vapour pressure
1.0 MPa
1.0 MPa
Refrigerant
R 407 C
R 407 C
Refrigerant quantity
0.6 kg
0,78 kg
Container volume, max.
5.8 l
5.8 l
“Tank full” LED comes up at
3.9 l
3.9 l
Room volume (at a ceiling height of 2.5 m)
150 – 200 m³
250 – 300 m³
Room area
60 – 80 m²
100 – 120 m²
Sound power level L
WA
< 70 dB (A)
< 70 dB (A)
Sound power pressure L
PA
53 dB (A)
53 dB (A)
Weight
51.5 kg
53.5 kg
Summary of Contents for ALE 600
Page 10: ...9 S Sc ch ha al lt tp pl la an n K Kä äl lt te ek kr re ei is sl la au uf f ...
Page 41: ...40 Z Zá ár ru uk ka a Prosíme přečtěte si přiložené záruční prohlášení ...
Page 51: ...50 G Ga ar ra an nt ti i Se venligst vedlagte garantierklæring ...
Page 70: ...69 S Sc ch ha ak ke el ls sc ch he em ma a K Ko oe el lc ci ir rc cu ui it t ...
Page 81: ...80 Z Zá ár ru uk ka a Prosíme prečítajte si priložené záručné prehlásenie ...