17
Maintenance
The air dehumidifier is designed for a trouble-free operation
and a minimum of maintenance.
All movable parts are permanently lubricated.
Inside the device, there are no other parts to be maintained.
S
S
t
t
o
o
r
r
a
a
g
g
e
e
Store unused equipment in a dry, locked place out of the
reach of children.
Note the following to extend the service life of your air
dehumidfier and to ensure a perfect function:
@
Drain the water collecting container and dry it carefully.
@
Clean the filter.
@
Thoroughly clean the device.
@
Check the air dehumidifier for perfect condition to ensure
a safe use of it after a longer period of storage.
@
Carefully cover the air dehumidifier.
P
P
o
o
s
s
s
s
i
i
b
b
l
l
e
e
f
f
a
a
u
u
l
l
t
t
s
s
Power off the device and disconnect the mains plug before each troubleshooting.
Fault
Possible cause
Corrective action
No power supply.
Check fuses.
Mains cable defective.
Have it checked (electrician).
Water collecting container full.
Drain the water collecting container.
Motor does not start
Humidity of the room air lower than the
set value.
Check the set humidity value and set another value
if required.
Room temperature or humidity of air out
of the working range.
a)
Check the room temperature (5 °C to 32 °C).
b)
Check the humidity of air (at least 30% RH).
c)
Check the set humidity value and set another
value if required.
Air filter contaminated.
Clean the air filter (see “Cleaning and
Maintenance”).
Air supply or exhaust air outlet blocked. Check. Place the device on another location of
required (adhere to the minimum distance to walls
(10 cm)).
a)
Interior of the device heavily
contaminated.
b)
Refrigerant circuit defective.
Contact the manufacturer or customer service.
Only little condensation or no water
Doors and/or windows open.
Close doors and/or windows.
a)
Drain hose kinked or wound up.
b)
Not enough descending gradient.
Re-route the drain hose to allow the water to flow
out unhindered.
Device shuts down in continuous
operation with drain hose
Water frozen in the hose.
Take precautions to avoid water freezing.
Fault
Possible cause
Corrective action
Water flows out of the device
Leakage of the water collecting
container.
a)
Check the water collecting container.
b)
Replace the water collecting container.
Device is placed on an uneven floor.
Place the device on an even floor.
Unusual noise or vibrations.
Screws, nuts or other parts loosened.
Tighten the parts.
If the parts cannot be tightened, are in the interior
of the device or the noise persists: Contact the
manufacturer or the responsible customer service
respectively
L
Please contact the manufacturer or the customer service if you cannot eliminate a fault although you have carried out all
functional tests.
L
Immediately put the device out of operation if it does not function properly.
Summary of Contents for ALE 600
Page 10: ...9 S Sc ch ha al lt tp pl la an n K Kä äl lt te ek kr re ei is sl la au uf f ...
Page 41: ...40 Z Zá ár ru uk ka a Prosíme přečtěte si přiložené záruční prohlášení ...
Page 51: ...50 G Ga ar ra an nt ti i Se venligst vedlagte garantierklæring ...
Page 70: ...69 S Sc ch ha ak ke el ls sc ch he em ma a K Ko oe el lc ci ir rc cu ui it t ...
Page 81: ...80 Z Zá ár ru uk ka a Prosíme prečítajte si priložené záručné prehlásenie ...