background image

4250.111  Edition 20

DH 26 - DH 44 - DH 62 - DH 92 - DH 100

DH 44DV - DH 62DV

USER AND MAINTENANCE BOOK

en

LIBRETTO USO E MANUTENZIONE

it

BEDIENUNGS- UND WARTUNGSANLEITUNG

de

MANUAL DE INSTRUCCIONES PARA EL USO Y MANTENIMIENTO

es

MANUEL D’UTILISATION ET DE MAINTENANCE

fr

HANDLEIDING VOOR GEBRUIK EN ONDERHOUD

nl

MANUAL DE USO E MANUTENÇÃO

pt

VEJLEDNING OM BRUG OG VEDLIGEHOLDELSE

da

KÄYTTÖ- JA HUOLTO-OHJE

fi

HEFTE FOR BRUK OG VEDLIKEHOLD

no

ANVÄNDAR- OCH UNDERHÅLLSHANDBOK

sv

INSTRUKCJA OBSŁUGI I KONSERWACJI

pl

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ

ru

PŘÍRUČKA PRO POUŽITÍ A ÚDRŽBU

cs

HASZNÁLATI ÉS KARBANTARTÁSI KÉZIKÖNYV

hu

PRIROČNIK Z NAVODILI ZA UPORABO IN VZDRŽEVANJE

sl

KULLANIM VE BAKIM K

i

TAPÇIĞI

tr

KNJIŽICA O UPORABI I ODRŽAVANJU

hr

NAUDOJIMO IR PRIEŽIŪROS KNYGELĖ

lt

LIETOŠANAS UN TEHNISKĀS APKOPES GRĀMATIŅA

lv

KASUTUS- JA HOOLDUSJUHEND

et

MANUAL DE UTILIZARE ŞI ÎNTREŢINERE

ro

PRÍRUČKA PRE POUŽITIE A ÚDRŽBU

sk

НАРЪЧНИК ЗА ИЗПОЛЗВАНЕ И ПОДДРЪЖКА

bg

КЕРІВНИЦТВО З ЕКСПЛУАТАЦІЇ Й ТЕХНІЧНОГО ОБСЛУГОВУВАННЯ

uk

ΕΓΧΕΙΡΙΔΙΟ ΧΡΗΣΗΣ ΚΑΙ ΣΥΝΤΗΡΗΣΗΣ

el

ПАЙДАЛАНУ ЖӘНЕ ТЕХНИКАЛЫҚ ҚЫЗМЕТ КӨРСЕТУ ЖЕТЕКШІЛІГІ

kk

Dantherm S.p.A.

Via Gardesana 11, -37010-

Pastrengo (VR), Italy

Dantherm S.p.A.

Виа Гардесана 11, 37010

Пастренго (Верона), Италия

Dantherm Sp. z o.o.

ul. Magazynowa 5A, 

62-023 Gądki, Poland

Dantherm Sp. z o.o.

ул. Магазинова, 5A,

62-023 Гадки, Польша

Dantherm LLC

ul. Transportnaya - 22 ownership 2,

142802, STUPINO, Moscow region, Russia

ООО «Дантерм»

Ул. Транспортная, владение 22/2,

142802, г.Ступино, Московская обл., РФ

Dantherm China LTD

Unit 2B, 512 Yunchuan Rd., 

Shanghai, 201906, China

Dantherm China LTD

Юньчуань роад, 512, строение 2В, 

Шанхай, 201906, Китай

Dantherm SP S.A.

C/Calabozos, 6 Polígono Industrial, 28108 

Alcobendas (Madrid) Spain

Dantherm SP S.A.

Ц/Калабозос, 6 Полигоно Индустриал, 

28108 Алкобендас (Мадрит) Испания

Summary of Contents for MASTER DH 26

Page 1: ...V hu PRIRO NIK Z NAVODILI ZA UPORABO IN VZDR EVANJE sl KULLANIM VE BAKIM KiTAP I I tr KNJI ICA O UPORABI I ODR AVANJU hr NAUDOJIMO IR PRIE I ROS KNYGEL lt LIETO ANAS UN TEHNISK S APKOPES GR MATI A lv...

Page 2: ...__________________________________________________________ _______________________________________________________________________________ _____________________________________________________________...

Page 3: ...0 W 3 1 A 220 240 V 50 Hz 890 W 4 4 A 220 240 V 50 Hz 1 200 W 6 A 220 240 V 50 Hz 1 250 W 6 A dB A 46 dB 53 dB 53 dB 50 dB 50 dB 8 l 12 l 12 l 12 l 12 l 30 kg 43 kg 47 kg 66 kg 69 kg 2 6 mPa LRA 9 A 2...

Page 4: ...8 8 A dB A 53 dB 53 dB 12 l 12 l 46 kg 50 kg 2 6 mPa LRA 16 A 220 240 V LRA 32 A 110 120 V 2 6 mPa LRA 21 6 A 220 240 V LRA 43 2 A 110 120 V CO2 Eq 1 5 1 4 GWP 4 4 30 C UR 80 30 80 IMPORTANT In order...

Page 5: ...IGURE ABBILDUNGEN FIGURAS FIGURES FIGUREN FIGU RAS FIGURER KUVAT FIGURER FIGURER ILUSTRACJE OBR ZKY BR K SLIKE EK LLER SLIKE ILIUSTRACIJOS ATT LI JOONISED IMAGINI OBR ZKY SLIKE 1 DH 26 DH 44 DH 62 DH...

Page 6: ...ICTURES FIGURE ABBILDUNGEN FIGURAS FIGURES FIGUREN FIGU RAS FIGURER KUVAT FIGURER FIGURER ILUSTRACJE OBR ZKY BR K SLIKE EK LLER SLIKE ILIUSTRACIJOS ATT LI JOONISED IMAGINI OBR ZKY SLIKE 2 3 6 1 5 4 3...

Page 7: ...ORKING FULL ON OFF HUMIDITY HOURS 0 240V I 110V PICTURES FIGURE ABBILDUNGEN FIGURAS FIGURES FIGUREN FIGU RAS FIGURER KUVAT FIGURER FIGURER ILUSTRACJE OBR ZKY BR K SLIKE EK LLER SLIKE ILIUSTRACIJOS ATT...

Page 8: ...6 7 5 PICTURES FIGURE ABBILDUNGEN FIGURAS FIGURES FIGUREN FIGU RAS FIGURER KUVAT FIGURER FIGURER ILUSTRACJE OBR ZKY BR K SLIKE EK LLER SLIKE ILIUSTRACIJOS ATT LI JOONISED IMAGINI OBR ZKY SLIKE...

Page 9: ...operation and main tenance of the unit must be performed Only by properly trained people who must implement safe working practices and use the personal protective equipment appropri ate to the specifi...

Page 10: ...the manufacturer The appliance must be placed in a room that does not have ignition sources con tinuously in operation e g open flames a gas appliance while running or an electric heater running Do no...

Page 11: ...sed collection or recycling centres follow the local regulations in force CAUTION Depending on the model as semble the appliance with any handles wheels and all relevant hardware FIG 3 housed inside t...

Page 12: ...the ON status but in stand by mode i e the compressor is off ALARM LED This LED is on when the unit is in alarm The display will show the error message WORKING LED This LED is on when the compressor...

Page 13: ...LTER FROM THE APPLIANCE TO PERFORM CLEANING IT IS FORBIDDEN TO PERFORM CLEAN ING WITH THE FILTER INSTALLED 5 2 SPARE PARTS Should it be required to replace one or more parts during maintenance by spec...

Page 14: ...temperature too low Room temperature conditions not suit able for operation ALARM Prob Humidity probe malfunc tion In any case the unit continues to function Contact the authorised assistance centre A...

Page 15: ...clare that it is compliant with Si dichiara che conforme a Es wird als konform mit den folgenden Normen erkl rt Se declara que est en conformidad con Nous d clarons sa conformit Hierbij wordt verklaar...