Chapter 2. Hardware Setup
16
b) To bypass RS-232 serial control signals to a PC or a serial device,
connect the PC or serial device (e.g., touch pad) to the unit’s RS-232
serial port and put the RS-232 serial communication switch to
Bypass
.
8. (Optional) Connect the power adapter to the unit’s power jack or connect a
PoH PSE-supported device to the unit’s HDBaseT input port for power
supply and operation.
RS-232 Channel Transmission
You can manage the VE2812R / VE2812PR via RS-232 serial devices, such as
computers or bar code scanners. The RS-232 signal transmission flow can be
illustrated as follows:
From a source device, the RS-232 signal is transmitted (Tx) to the VE2812R /
VE2812PR receiving (Rx) unit; the a compatible ATEN Video Receiver
transmits (Tx) signals to the display device (Rx).
You can set the VE2812R / VE2812PR to either bypass serial data or to receive
RS-232 commands. By default, the VE2812R / VE2812PR is set to bypass
serial data. To set the unit to receive RS-232 commands, press the Input Switch
pushbutton for 5 seconds. For details on RS-232 commands, see
PIN
CONFIGURATION
(Captive screw
connectors)
Tx
Rx
Gnd
Tx
Rx
Gnd
Tx
Rx
Gnd
Tx
Rx
Gnd
Serial
Device
Cat 5e / 6 / 6a