![Atek ADR 50 Series Instruction Manual Download Page 41](http://html.mh-extra.com/html/atek/adr-50-series/adr-50-series_instruction-manual_2997119041.webp)
[40]
If the “Main Menu” is selected from these modes;
The depth value of electrode is entered on the "Depth" line. If the workpiece surface “0” is accepted, the depth
value should be entered minus.The error which may arise from the electrode is entered on the "Offset" line.For
example, due to the electrode wear caused in time, the depth difference is adjusted by giving a value on the "Offset"
line. It is selected of relay contact position; normally open or normally close.The operation axis is selected on the
"Axis" line.
When selected "Main Menu" if the desired value is over than the value of " Depth" the relay pulls, if under
the relay leaves while working on main menu screen.
When the function startup the simulation screen will be
open like a side. The current position is shown with a
yellow marker.
The yellow line shows the value of depth, the pink line
is depth + offset value.Operation is made according to
value of pink. The axis values shows on the left side at
the same time. The active axis white, others are blue.
During the function active, the red led which next to
image of EDM is blinking.
The action is displayed on the screen until Axis reaches
the desired value.
The electrode moves in negative direction until yellow
pointer reach to pink line and the relay is not changed
on position.
The function can be paused with "Hold" button and
continue with "ENT" button.
If Axis is moved in positive direction the "Max.Depth"
value is displayed in white color on the left side.
The reminder about simulation is located in information
box on the right side.
When the value reach the “ Depth”(pink line) ADR
gives beeps and the relay is change on position.
Press “ENT” button to start the process again
Axis values can be reset with "Reset" button while the
simulation screen.