Operating instructions AQUAMAX
®
PRO G
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0272 / Status: 24 February 2021 / Page 14 from 36
Runtimes
Display of the weekly or accumulated run times (cumulative).
Events
Documentation of manual interventions.
Example: acoustic alarm and subsequent manual reset of this alarm
Messages
Each change is documented in the message logbook. For example, when a
float switch has switched, or when a pump switched ON or OFF.
Save logbooks to USB stick
You have the possibility to save the logbooks on a USB stick.
To do this, loosen the 4 screws of the display cover (not the terminal box),
open the cover carefully (ATTENTION! Connecting cable!), turn it over and
insert the USB stick into the corresponding socket on the board.
On the bottom line of the display, the [USB] message appears to indicate
that the USB key has been detected.
From the Info screen, pressing OK + ▲ at the same time starts writing the
logbooks to the USB stick. 5 files are saved one after the other in Excel
format in the currently set language. When the files are saved, [WLOG]
appears on the bottom line of the display. A beep sounds after each file
download. When the 5th file has been completed, a signal consisting of 4
beeps is heard. The USB stick can now be removed.
L
L
O
O
G
G
B
B
O
O
O
O
K
K