The Configuration Map
4-12
Issue 2 April 1996
Table 4-8.
Screen Heading
Field
Description
Application
Name
DEFINITY G3 FM
Switch Name
The name of the PBX as it appears on the NMS when the
PBX is administered as a node on the network. This
information is passed from the NMS.
Cabinet Number
The number of the current cabinet.
Circuit Pack
Mismatches
The number of circuit packs with a mismatch between the
type that is inserted into the cabinet slot and the type that
is administered for that slot.
A mismatch is the highest level of severity, and
supersedes alarms.
You can set the background color in the Circuit Pack
Mismatch Color field on the Setup screen.
Fault Management displays this field only when
mismatches exist.
Table 4-9.
Alarms
The color-coded alarms on the right side of the screen display the number of
major, minor, and warning alarms as follows:
■
Cabinet alarms that are on the cabinet but are not associated with a
circuit pack
■
Pack alarms that are specifically associated with a circuit pack
Refer to Figure 4-1 for an illustration of the alarms box.
Summary of Contents for OneVision DEFINITY G3 Fault Management and integration
Page 26: ...Introduction 1 14 Issue 2 April 1996 Figure 1 4 Trap Message for External Devices ...
Page 64: ...Port Information Issue 2 April 1996 4 21 Figure 4 6 Port Information Pooled Modem ...
Page 65: ...The Configuration Map 4 22 Issue 2 April 1996 Figure 4 7 Port Information Station ...
Page 66: ...Port Information Issue 2 April 1996 4 23 Figure 4 8 Port Information Data Module ...
Page 74: ...External Devices Issue 2 April 1996 4 31 Figure 4 10 External Devices View ...
Page 114: ...Report Builder 7 4 Issue 2 April 1996 Figure 7 1 Report Builder Screen ...