POWER FAILURES
TABLE 3-1 Out-of-service Codes
Number
of Blinks
Problem
1
Announcements were not recorded or were
erased (slow blink) or cannot compute battery
level (fast blink).
2
Unable to turn Voice Recorder off.
3
Unable to turn Voice Recorder on.
4
Unable to turn Voice Playback off.
5
Unable to turn Voice Playback on.
6
Announcement detected with no time allocation.
7
Attempt made to play an unrecorded
announcement.
8
RAM constants pool corruption detected.
9
ROM check-sum error detected.
10
Invalid value read from Real-Time Clock.
During a power failure, the MERLIN Attendant can
maintain all of its programming information (i.e., routes,
business schedule, authorization code) up to eight weeks
and all recorded announcements up to three hours if the
MERLIN Attendant battery was fully charged and
switches 1 and 2 were in the ON position at the time of the
power failure.
It takes 18 hours of continuous power to charge the
battery.