reset
This recessed button resets the MERLIN Attendant.
See “Troubleshooting” for details.
setup switches
There are four setup switches. Switches 1,2, and 3
control the MERLIN Attendant response to a power
outage as shown in Table 1-2; switch 4 is not used.
TABLE 1-2 Meaning of Setup Switch Settings
Switch
1
2
3
4
On (Down)
Off (up)
Recorded
Recorded
announcements are
announcements are
retained during a
erased during a power
power outage
outage
Routes and other
Routes and other
programming
programming
parameters are
parameters are reset to
retained during a
defaults during a
power outage
power outage
The MERLIN
The MERLIN
Attendant continues to
Attendant does not
answer calls during a
answer calls during a
power outage
power outage
Not Used
Not Used
CAUTION:
After connecting ac power to the MERLIN
Attendant, be sure that switches 1 and 2 are
on
(down).
With this setting, recorded announcements are saved up
to three hours during a power outage (if the battery is
fully charged) and routing plans and programming
parameters are retained up to eight weeks.