6
53
ASUS PCI-DA2100/PCI-DA2200 User’s Manual
Chapter 6 Configuring RAID
6.1 Starting to Build a RAID System Drive
The following figure is a basic flowchart when configuring a RAID
system. Hardware installation must be completed before any
configurations take place.
When power is turned on, the ASUS PCI-DA2100/-DA2200 RAID
controller scans all the hard drives that are on all the drive channels.
If a hard drive was connected after the controller completes
initialization, use the "SCAN SCSI DRIVE" function to let the
controller recognize the newly added hard drive and configure it as a
member of a logical drive or a spare drive.
In accordance to your requirement, configure a logical drive to
contain one or more hard drives based on the desired RAID level,
and partition the logical drive into one or several partitions. Map
each partition as one system drive (LUN). The host SCSI adapter will
recognize the system drives after re-scanning the host SCSI bus.
Since the controller is totally operating system independent, the
operating system of the host computer will not be able to find out
whether the attached devices are physical hard drives or virtual
system drives created by the RAID controller.
NOTE:
A “Logical Drive” is a set of drives grouped together to operate under a
given RAID level and appears as a single contiguous drive. The ASUS PCI-
DA2100/-DA2200 controller is capable of grouping connected drives to as
many as 8 logical drives, each configured on the same or different RAID
levels. A logical drive can be further divided into a maximum of 8
“Partitions”. During operation, the host sees an unpartitioned logical drive
or a partition of a partitioned logical drive as one single physical drive.
Create
Logical Drive
Partition
Logical Drive
Map
Host LUN
(System Drive)
Summary of Contents for PCI-DA2200
Page 8: ...1 8 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Page 40: ...3 40 ASUS PCI DA2100 PCI DA2200 User s Manual Drive E now has a capacity just under 1800MB ...
Page 58: ...6 58 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Page 138: ...9 138 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Page 184: ...Appendix B 184 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Page 188: ...Appendix D 188 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Page 208: ...Index ASUS PCI DA2100 PCI DA2200 User s Manual 208 This page is left intentionally blank ...
Page 209: ...GUI RAID Manager For ASUS Disk Array Controllers User s Guide Revision 1 5 ...
Page 226: ...ASUS GUI RAID Manager Introduction 1 3 Feature Highlights 1 11 ...