4-46
Chapter 4: BIOS Setup
4.7
Monitor menu
The Monitor menu displays the system temperature/power status, and allows you to change
the fan settings.
Scroll down to display the other BIOS items.
CPU1 Temperature / TR1 Temperature [xxx°C/xxx°F]
The onboard hardware monitor automatically detects and displays the CPU and the
motherboard temperatures. Select
[Ignore]
if you do not wish to display the detected
temperatures.
CPU FAN1-2 Speed [xxxx RPM] or [Ignore] / [N/A], REAR FAN1 Speed [xxxx
RPM] or [Ignore], FRNT FAN1-3 Speed [xxxx RPM] or [Ignore] / [N/A]
The onboard hardware monitor automatically detects and displays the CPU, chassis,
and power fan speed in rotations per minute (RPM). If the fan is not connected to the
motherboard, the field shows N/A. Select
[Ignore]
if you do not wish to display the detected
speed.
+VCCIO, +VCORE1, +VDDQ_AB, +VDDQ_CD, +5VSB, +5V, +12V, +3.3V, VBAT,
+3.3VSB Voltages
The onboard hardware monitor automatically detects the voltage output through the onboard
voltage regulators. Select
[Ignore]
if you do not want to detect this item.