7
Default Setting
You may believe that a product as versatile as this one would be a programming nightmare. In most cases, you will
not need to change a setting from the factory default programming
Consult the following charts to determine if the defaults work for the installation. If no changes are required, move to
the testing phase of the installation on page 25. If, for any reason, changes to the default programming are required,
please become familiar with the programming charts, beginning on page 17.
TOPIC
DEFAULT FEATURES FOR STAGE 1
LEVEL
Transmitters
• No modification required unless additional remotes need to be learned.
They are all factory programmed in User 1.
Level 1
Page 17
Tach/Engine
• 1 cylinder - 800 RPM idle speed
Level 2
Page 17
Engine
configuration
• Circuit “P2-5” used for Parking light detection
• Parking Light or Glow Plugs circuit polarity is Positive (+)
• Ignition cuts off between crank cycles
• Hood switch closed contact when hood is open
Level 3
Page 18
Anti-theft
compatibility
• No accessory delay after start-up
• Rearming disabled
• Anti-theft disabled
Level 4
Page 18
Programmable
output 1
• Pulse before Start and with Unlock
Level 5
Page 19
Programmable
output 2
• Pulse after runtime and with Lock
Level 6
Page 19
Programmable
output 3
• Trunk opening
Level 7
Page 19
Programmable
output 4
• Dome light supervision
Level 8
Page 19
Programmable
Relay
• Active while running
Level 9
Page 20
Door lock
options
• 0.7 sec. pulse before ignition
• 0.7 sec. lock/unlock pulse
• Auto lock disabled
• Unlocking pulse = Single
• 2nd locking confirmation disabled
Level 10
Page 20
Utility outputs
• Utility output #1 and #2 = 0.7 second pulse
• Utility output #3 and #4 = 0.7 second pulse (no configuration)
• 30 seconds Panic/Alarm duration
Level 11
Page 21
Start cycle
options
• Over-revving supervision = Enabled
• Pulse before start on all Unlock outputs = Disabled
• Pulse after start on all Lock outputs = Disabled
• Runtime = 8 min. (Gas) / 16 min. (Diesel)
Level 12
Page 21
Sentinel Mode
• Sentinel mode temperature = -15º C (5º F)
• Sentinel mode runtime = 8 min. (Gasoline) / 16 min. (Diesel)
• Pulse before on Trunk command = Disabled
Level 13
Page 21
Alarm
• AstroStart Alarm = Disabled
• Chirp = Enabled
• Additional sensor = Other sensor
Level 14
Page 22
Remote options
• Trunk command use for Trunk opening
Level 15
Page 22
Vehicle
configuration
• Manual Transmission car type
• Sequence initialized by 2 parking brake activations
Level 16
Page 22
Summary of Contents for BBF
Page 30: ...28...