PROGRAMMING THE TABBER
62
10.
Pitch of tab is distance measured from
top of one tab to top of next tab. This is
done by selecting
Pitch
from
“
Select
option to edit
”
screen. Measure
distance from top of one tab to top of
next tab. In this case, it was 1.630".
Then add 0.01" for a total of 1.64".
Enter that number using number keys
on Control Panel, then pressing
SAVE
key.
11.
Press
BACK
one time to return to
“
Select option to edit
”
screen and
select
Position
.
12.
Each of two tab positions must be
entered. Position of tab is measured
from lead edge of piece (
exit end
)
separately. Begin by measuring piece
length and deciding where first tab will
be placed. In this example, Post Office
requires that first tab be positioned less
than 1/2" from bottom of piece.
Press
Tab 1
.
13.
Position of Tab 1 should not be greater
than 1/2" from bottom (
lead
) edge.
Enter 0.4900" using Number keys on
Control Panel, press
SAVE
key and
then
BACK
key.