background image

 

 

21. 

OPERATING INSTRUCTIONS 

● 

CONTINUOUS RED LIGHT

 

– Indicates AC power is on. 

 

● 

SLOW BLINKING RED LIGHT

 

– Indicates a Weak Battery. 

 

● 

FAST BLINKING RED LIGHT

 

– Before charge this indicates battery is connected backwards, check connection. 

 

● 

CONTINUOUS GREEN LIGHT

 - Indicates correct connection.  If when battery is connected, the green light does not light, check for 

proper polarity or poor connections.  If the battery voltage is below 4 volts the green light will not come on.  (See Dead Battery Override 
operation paragraph) 

● 

CONTINUOUS YELLOW LIGHT

 - Indicates charging. 

 

● 

BLINKING YELLOW LIGHT

 - Indicates battery is near end of charge and is in the finish charge mode. 

 

● 

BLINKING GREEN LIGHT

 - Indicates charging is complete and is in the float mode. 

 

● 

FLASHING GREEN AND YELLOW LIGHTS

 - Indicates first stage of deep discharge recovery process. 

 

NOTES:

 

FIVE SECOND DELAY

 

– To avoid sparking the charger control tests for correct polarity before applying current to the battery.  When 

connected properly, the green light will come on for 5 seconds before the yellow light comes on. 
 

BATTERY TEST

 - During the 5 second period when the green light is on, the charger will test for a deep discharged battery. 

 

BATTERY CHARGE

 

– After testing the battery, the control will select a charging rate suitable for the voltage and state of charge of the battery. 

 A small battery or a nearly charged battery will cause the charger to rapidly step down in current to avoid heating and gassing. 
 

FINISH CHARGE

 

– In order to reach a 100 % state of charge on the battery, a finish charge cycle has been programmed into the charger.  

During the finish cycle, the yellow light will blink.  If the battery is good, there will be enough charge in the battery at this time to start a vehicle 
when the yellow light is blinkin

g.  If desired, the battery can be removed and replaced in the vehicle.  The vehicle’s alternator will finish charging 

the battery. 
NOTE: To avoid sparking, always turn off power switch to disconnect charger power. 
 

BATTERY MAINTAINER

 

– After charge is complete the charger will go to a float charge to maintain battery. 

 

DEEP DISCHARGE RECOVERY

 

– If the charger determines a battery is deeply discharged, it will attempt to recover the battery with a 

program designed to enhance charge acceptance.  Because of the voltage levels required for recovery, this program is not included for sealed 
batteries. 
 

OPERATING PROCEDURE: 

1.

 

Turn on Power Switch.  The Red light should come on. 

2.

 

Select Battery Type. 

3.

 

Connect the POSITIVE (RED) clamp to the positive (+) terminal of the battery. Connect the NEGATIVE clamp to the negative (-) terminal 
of the battery.  The GREEN light will come on for about 5 seconds. 

4.

 

The YELLOW light will come on when the GREEN light goes off and charging will begin. 

5.

 

If the battery is deeply discharged and in flooded setting, the YELLOW and GREEN lights will flash on and off for up to 30 minutes. 

6.

 

The battery is between 80% and 99% state of charge when the YELLOW light blinks.  The charger is in the finish charge mode. 

7.

 

The battery has been fully charged when the GREEN light is blinking.  The charger maintains battery at a float voltage. 

 

NOTES

a.

 

If the charger is connected to a fully charged battery the charger will go into the finish charge mode then shut off and the GREEN light will 
blink. 

b.

 

Not all deeply discharged batteries can be recovered. 

c.

 

Some batteries which have been recovered from a deep discharge will maintain an acceptable open circuit terminal voltage but have a 
reduced capacity under load.  Always load test or otherwise test a recovered battery to determine if the CCA capacity is within 80% of the 
rated value. 

d.

 

Any time a malfunction is suspected reset the control by turning AC Switch on and off. 

 

DEAD BATTERY OVERRIDE 

If the battery voltage is below 3V the battery charger will not recognize that it has been connected to a battery.  Most batteries even if 
completely discharged will recover to a voltage greater than 3V, but if a battery is left in a discharged state for an extended period of time the 
voltage may fall below 3V.  Circuit -2 has been equipped with a Dead Battery Override switch; this can be used to start the charger if the battery 
voltage is below 3V. 

OPERATION: 

a.

 

Connect the deeply discharged battery to circuit-2, battery should be placed as far away from the charger as the cables will allow.  (See 
Section 18) 

b.

 

Press and hold the override switch; green LED should light, if monitoring the battery voltage should see it rise. 

CAUTION:

 

Never press the override switch without a battery connected

c.

 

After several seconds release the override switch, if the battery will accept a charge it should now start charging.  For best results the 
Battery Type switch should be set for flooded.  If the battery is a sealed type; the Battery Type switch can be changed after the battery has 
reached the gassing point (yellow LED starts to flash).  The battery may have to be connected to the charger several times before the 
charger will not fail it as a bad battery (red LED flashing) the operator should only need to press the override for the first attempt to recover 
the battery. 

Summary of Contents for 6366

Page 1: ...vicinity of the battery Review cautionary markings on these products and on the engine 13 PERSONAL PRECAUTIONS a Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and clothing protection Avoid touching ...

Page 2: ... battery d Position yourself and free end of cable as far away from the battery as possible then connect the NEGATIVE charger cable to the free end of cable e Do not face the battery when making the final connection f When disconnecting the charger always do so in reverse sequence of connecting procedure and break the first connection while standing as far away from the battery as practical g A ma...

Page 3: ...y Type 3 Connect the POSITIVE RED clamp to the positive terminal of the battery Connect the NEGATIVE clamp to the negative terminal of the battery The GREEN light will come on for about 5 seconds 4 The YELLOW light will come on when the GREEN light goes off and charging will begin 5 If the battery is deeply discharged and in flooded setting the YELLOW and GREEN lights will flash on and off for up ...

Page 4: ...se 610054 5 Side panel 1 pair 610253 6 Power switch 610272 7 Circuit board 1ea 611181 8 Switch Battery type 1ea 611000 9 Receptacle w 6 leads 1 ea 611182 10 Receptacle w 9 11 leads 1 ea 611186 11 AC cord 611185 12 Fan motor 610632 13 Fan blade 610189 14 Feet 4 pcs 610639 15 Override switch 1 ea 611022 16 Back panel 611410 Not Shown Breaker 2 pcs 610987 DC cable 1 ea 611183 ...

Page 5: ...ou de tout autre équipement devant être utilisé près d une batterie Revoir les avertissements indiqués sur ces produits et sur le moteur 13 PRÉCAUTIONS PERSONNELLES a S assurer que quelqu un est à portée de voix ou suffisamment près pour prêter assistance lorsqu on travaille près d une batterie au plomb b Avoir à la portée de la main une réserve suffisante d eau fraîche et du savon au cas où l aci...

Page 6: ...erie et dégager l extrémité du câble puis brancher le câble négatif du chargeur à l extrémité du câble e Ne pas faire face à la batterie pour effectuer le dernier branchement f Pour débrancher le chargeur suivre en sens inverse les étapes relatives au branchement et débrancher la première connexion tout en se tenant aussi loin que possible de la batterie g Les batteries pour bateaux doivent être d...

Page 7: ...Le voyant rouge devrait s allumer 2 Sélectionner le type de batterie 3 Brancher la pince POSITIVE ROUGE sur la borne positive de la batterie Brancher la pince NÉGATIVE á la borne négative de la batterie Le voyant VERT devrait s allumer pendant environ 5 secondes 4 Le voyant JAUNE devrait s allume lorsque le voyant VERT s éteint ce qui indique le début de la charge 5 Si la batterie est entièrement ...

Page 8: ...avec 9 11 conduit 611186 11 Jeu de câbles C A 611185 12 Moteur de ventilateur 610632 13 Pale de ventilateur 610189 14 Pied 610639 15 Commutateur de Priorité 611022 16 Panneau Arrière 611410 Non Représenté Disjoncteur C C Masqué 610987 Jeu de câbles C C Masqué 611183 INSTRUCTIONS D ENTRETIEN Des pièces usées peuvent causer une mauvaise connexion et par là même poser un danger pour l utilisateur Voi...

Page 9: ...lomo d Si el ácido de la batería contacta su piel o ropa lávese inmediatamente con agua y jabón Si el ácido contacta sus ojos lávelos inmediatamente con agua corriente fresca durante al menos 10 minutos y obtenga atención médica e NUNCA fume o produzca chispas o llamas cerca de la batería o del motor f Sea muy cuidadoso para evitar que una herramienta de metal caiga encima de la batería Podría cau...

Page 10: ...go de shock eléctrico El cargador está equipado con un cable y enchufe diseñados para tal conexión El enchufe debe estar conectado a una toma que esté correctamente instalada y conectada a tierra de acuerdo con todos los códigos y ordenanzas locales PELIGRO Nunca cambie el cable o enchufe AC provisto en el cargador Si no se adapta a la toma de corriente haga que un electricista cualificado la camb...

Page 11: ...ndo la batería se encuentre cargada entre un 80 y un 99 la luz AMARRILLA comenzará a parpadear EI cargador se encuentra en el modo Terminar carga 7 Cuando la batería está totalmente cargada la luz VERDE comenzará a parpadear El cargador mantiene la batería a un voltaje de flotación NOTAS a Si el cargador está conectado a una batería totalmente cargada pasará al modo Terminar carga y luego se apaga...

Page 12: ... 610639 15 Interruptor Momentáneo 611022 16 Panel Posterior 611410 No se muestra Circuito Protector DC no se muestra 610987 Cordón DC no se muestra 611183 INSTRUCCIONES DE MANTENIMIENTO Piezas corroídas pueden producir malas conexiones y puede ser peligroso Mirar la lista de piezas por el cordón de DC Cualquier reparación o mantenimiento de esta unidad que lleve con sigo desarmar la cabina debe se...

Reviews: