15. 

CHARGER LOCATION

 

a.

 

Locate the charger as far away from the battery as the DC cables permit. 

b.

 

Never place the charger directly above the battery being charged; gases from the battery will corrode and damage the charger. 

c.

 

Never allow battery acid to drop on the charger when reading the specific gravity or filling battery, 

d.

 

Do not operate the charger in a closed-in area or restrict ventilation in any way. 

e.

 

Do not set a battery on top of the charger. 

 

16. 

DC CONNECTION PRECAUTIONS

 

a.

 

Connect and disconnect the DC output cables only after removing the AC cord from the electric outlet.  Never allow the cable terminals to 
touch each other. 

 

17.

 

FOLLOW THESE STEPS WHEN THE BATTERY IS INSTALLED IN A VEHICLE.  A SPARK NEAR THE BATTERY MAY 
CAUSE A BATTERY EXPLOSION.  TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY: 

a.

 

Position the AC and DC cords to reduce the risk of damage by the hood, door, or moving engine parts. 

b.

 

Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons. 

c.

 

Check the polarity of the battery post.  The POSITIVE (POS, P, +) battery post usually has a larger diameter than the NEGATIVE (NEG, N, 
–) post. 

d.

 

Determine which post of the battery is grounded (connected) to the chassis.  If the negative post is grounded to the chassis (as in most 
vehicles), see item "e".  If the positive post is grounded to the chassis, see item "f". 

e.

 

For negative-grounded vehicles, connect the POSITIVE (RED) cable from the battery charger to the POSITIVE (POS, P, +) ungrounded 
post of the battery.  Connect the NEGATIVE cable to the NEGATIVE (NEG, N, 

–) battery post. 

f.

 

For positive-grounded vehicle, connect NEGATIVE cable from the battery charger to the NEGATIVE (NEG, N, 

–) ungrounded post of the 

battery.  Connect POSITIVE (RED) cable to the POSITIVE (POS, P, +) battery post. 

g.

 

When disconnecting the charger, disconnect the AC cord, remove the cable from the grounded battery post and then remove the cable 
from the ungrounded battery post. 

h.

 

See the operating instructions for length of charge information. 

 

18.

 

FOLLOW THESE STEPS WHEN THE BATTERY IS OUTSIDE THE VEHICLE.  A SPARK NEAR THE BATTERY MAY 
CAUSE A BATTERY EXPLOSION.  TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY: 

a.

 

Check the polarity of the battery post.  The POSITIVE (POS, P, +) usually has a larger diameter than the NEGATIVE (NEG, N, 

–) post. 

b.

 

Attach at least a 24-inch-long 6-gauge (AWG) insulated battery cable to the NEGATIVE (NEG, N, 

–) battery post. 

c.

 

Connect the POSITIVE (RED) charger cable to the POSITIVE (POS, P, +) post of the battery. 

d.

 

Position yourself and free end of cable as far away from the battery as possible - then connect the NEGATIVE charger cable to the free 
end of cable. 

e.

 

Do not face the battery when making the final connection. 

f.

 

When disconnecting the charger, always do so in reverse sequence of connecting procedure, and break the first connection while 
standing as far away from the battery as practical. 

g.

 

A marine (boat) battery must be removed and charged on shore.  To charge it on board requires equipment specially designed for marine 
use. 

 

19. 

GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

 

The charger should be grounded to reduce the risk of electric shock.  This charger is equipped with an electric cord having an equipment 
grounding conductor and a grounding plug.  The plug must be plugged into an outlet that is properly installed and grounded in accordance with 
all local codes and ordinances. 

DANGER

 Never alter the AC cord or plug provided - if it will not fit the 

outlet, have a proper outlet installed by a qualified electrician.  Improper 
connection can result in a risk of an electric shock.  This battery charger is for 
use on a nominal 120-volt circuit and has a grounding plug that looks like the 
plug illustrated in FIGURE (A).  A temporary adapter, which looks like the 
adapter illustrated in FIGURE (C), may be used to connect this plug to a two-
pole receptacle, as shown in FIGURE (B), until a properly grounded outlet can 
be installed by a qualified electrician. 

DANGER.

  

Before using an adapter as illustrated, be certain that the center screw of the outlet plate is grounded.  The green-colored rigid 

ear or lug extending from the adapter must be connected to a properly grounded outlet - make certain it is grounded.  If necessary, replace the 
original outlet cover plate screw with a longer screw that will secure the adapter ear or lug to the outlet cover plate and make ground connection 
to grounded outlet. 

 

NOTE:

 USE OF AN ADAPTER IS NOT ALLOWED IN CANADA.  IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO NOT USE 

THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN. 

 

20. 

CHARGE PERIOD 

The approximate required time to bring a battery to full charge state depends upon the number of amperes-hours (AH) depleted from the 
battery.  AHs are determined by multiplying the number of hours times the number of Amps supplied by a battery to a load and normally 
indicated on the battery.  For example, - if a load was connected to a battery, which drew 7 Amps for a period of 5 hours, the battery will have 
supplied 35 AH. The approximate recharge time would then be calculated by dividing the 35 AH depleted from the battery, by the ampere 
charge rate of the charger.  To allow for tapering of the charge rate add 25 percent to the charge time. 

 

Summary of Contents for 6366

Page 1: ...vicinity of the battery Review cautionary markings on these products and on the engine 13 PERSONAL PRECAUTIONS a Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and clothing protection Avoid touching ...

Page 2: ... battery d Position yourself and free end of cable as far away from the battery as possible then connect the NEGATIVE charger cable to the free end of cable e Do not face the battery when making the final connection f When disconnecting the charger always do so in reverse sequence of connecting procedure and break the first connection while standing as far away from the battery as practical g A ma...

Page 3: ...y Type 3 Connect the POSITIVE RED clamp to the positive terminal of the battery Connect the NEGATIVE clamp to the negative terminal of the battery The GREEN light will come on for about 5 seconds 4 The YELLOW light will come on when the GREEN light goes off and charging will begin 5 If the battery is deeply discharged and in flooded setting the YELLOW and GREEN lights will flash on and off for up ...

Page 4: ...se 610054 5 Side panel 1 pair 610253 6 Power switch 610272 7 Circuit board 1ea 611181 8 Switch Battery type 1ea 611000 9 Receptacle w 6 leads 1 ea 611182 10 Receptacle w 9 11 leads 1 ea 611186 11 AC cord 611185 12 Fan motor 610632 13 Fan blade 610189 14 Feet 4 pcs 610639 15 Override switch 1 ea 611022 16 Back panel 611410 Not Shown Breaker 2 pcs 610987 DC cable 1 ea 611183 ...

Page 5: ...ou de tout autre équipement devant être utilisé près d une batterie Revoir les avertissements indiqués sur ces produits et sur le moteur 13 PRÉCAUTIONS PERSONNELLES a S assurer que quelqu un est à portée de voix ou suffisamment près pour prêter assistance lorsqu on travaille près d une batterie au plomb b Avoir à la portée de la main une réserve suffisante d eau fraîche et du savon au cas où l aci...

Page 6: ...erie et dégager l extrémité du câble puis brancher le câble négatif du chargeur à l extrémité du câble e Ne pas faire face à la batterie pour effectuer le dernier branchement f Pour débrancher le chargeur suivre en sens inverse les étapes relatives au branchement et débrancher la première connexion tout en se tenant aussi loin que possible de la batterie g Les batteries pour bateaux doivent être d...

Page 7: ...Le voyant rouge devrait s allumer 2 Sélectionner le type de batterie 3 Brancher la pince POSITIVE ROUGE sur la borne positive de la batterie Brancher la pince NÉGATIVE á la borne négative de la batterie Le voyant VERT devrait s allumer pendant environ 5 secondes 4 Le voyant JAUNE devrait s allume lorsque le voyant VERT s éteint ce qui indique le début de la charge 5 Si la batterie est entièrement ...

Page 8: ...avec 9 11 conduit 611186 11 Jeu de câbles C A 611185 12 Moteur de ventilateur 610632 13 Pale de ventilateur 610189 14 Pied 610639 15 Commutateur de Priorité 611022 16 Panneau Arrière 611410 Non Représenté Disjoncteur C C Masqué 610987 Jeu de câbles C C Masqué 611183 INSTRUCTIONS D ENTRETIEN Des pièces usées peuvent causer une mauvaise connexion et par là même poser un danger pour l utilisateur Voi...

Page 9: ...lomo d Si el ácido de la batería contacta su piel o ropa lávese inmediatamente con agua y jabón Si el ácido contacta sus ojos lávelos inmediatamente con agua corriente fresca durante al menos 10 minutos y obtenga atención médica e NUNCA fume o produzca chispas o llamas cerca de la batería o del motor f Sea muy cuidadoso para evitar que una herramienta de metal caiga encima de la batería Podría cau...

Page 10: ...go de shock eléctrico El cargador está equipado con un cable y enchufe diseñados para tal conexión El enchufe debe estar conectado a una toma que esté correctamente instalada y conectada a tierra de acuerdo con todos los códigos y ordenanzas locales PELIGRO Nunca cambie el cable o enchufe AC provisto en el cargador Si no se adapta a la toma de corriente haga que un electricista cualificado la camb...

Page 11: ...ndo la batería se encuentre cargada entre un 80 y un 99 la luz AMARRILLA comenzará a parpadear EI cargador se encuentra en el modo Terminar carga 7 Cuando la batería está totalmente cargada la luz VERDE comenzará a parpadear El cargador mantiene la batería a un voltaje de flotación NOTAS a Si el cargador está conectado a una batería totalmente cargada pasará al modo Terminar carga y luego se apaga...

Page 12: ... 610639 15 Interruptor Momentáneo 611022 16 Panel Posterior 611410 No se muestra Circuito Protector DC no se muestra 610987 Cordón DC no se muestra 611183 INSTRUCCIONES DE MANTENIMIENTO Piezas corroídas pueden producir malas conexiones y puede ser peligroso Mirar la lista de piezas por el cordón de DC Cualquier reparación o mantenimiento de esta unidad que lleve con sigo desarmar la cabina debe se...

Reviews: