6.8
RE-FITTING THE RECEPTOR STRIP FRAME
1.
Place the Receptor Strip Frame back into the cabinet and slide into place. To ensure the strip frame is correctly in
place pull the bottom plunger and slide the bottom of the strip frame into position. Next pull the top plunger and
secure the top of the strip frame.
NOTE:
Be careful not to scratch the metalwork when replacing the strip frame.
NOTE:
Ensure the washer placed over the bottom plunger is still present and undamaged.
2.
Ensure the plungers are fully engaged into the strip frame. Test this by pulling the strip frame whilst it is in the
cabinet to ensure that it cannot be pulled out or removed in any way without re-releasing the plungers.
3.
Reconnect the earth and ribbon cables that were disconnected when you removed the strip frame.
4.
The strip frame can now be left open at 90°.
5.
Close the strip frame and replace the 2 Torx Pin screws, and then close the cabinet door.