MLC 60 Series • Setup Guide 

for the MLC 62 RS EU and the MLC 62 RS MK

The Extron MLC 62 RS EU and the MLC 62 RS MK 
are keypad controllers for use in classrooms and 
meeting facilities. The EU model attaches to a 
single size European electrical junction box with a 
60 mm mounting center; the MK model mounts to 
a single size MK junction box. The controllers have 
backlit soft touch buttons and can control common 
AV functions, including power, input switching, and 
volume. Both models provide RS-232 serial and IR 
ports for universal display control. A digital input 
and two relays enable monitoring and controlling 
of other devices in the room. Both models have 
six-button and eight-button options.

NOTES:

 

  Installation and service must be performed by authorized personnel only. 

• 

For full installation, configuration, and operation details, see the 

MLC 60 Series User Guide

, available at 

www.extron.com

.

Installation Steps

1. 

Prepare the installation site. 

The MLC 62 EU and MK controllers can be installed in a 
standard EU or MK one-gang electrical wall box:

a. 

Install the electrical box, following the instructions 
provided with it. 

CAUTION: 

Ensure that the junction box is 

 

 

properly grounded.

b. 

Prepare and pull the cables through the electrical 
box. 

2. 

(Optional) Change the faceplate and buttons as needed.

a. 

Remove the faceplate from the MLC module as follows:

i. 

On the right and left edges of the faceplate are two pairs of slots, into 
which two small tabs on either side of the MLC fit. Insert the flat end 
of a small screwdriver into each side slot (as shown at right) and press 
inward until the tab is released from its slot. 

ii. 

Lift the faceplate off the MLC circuit board.

b. 

If desired, replace the buttons in the faceplate as follows:

i. 

From the front of the faceplate, press the button membrane to be 
replaced backward through its faceplate openings until it comes free. 
If replacing the faceplate, repeat this step until all the buttons are 
removed.

ii. 

On the back of the faceplate, set the new button membrane at the 
desired location, with the two pegs in the upper-left and lower-right 
corners of the membrane in the faceplate holes at opposite corners of the 
row (see the illustrations at left and at right). Press the pegs and buttons 
of the membrane into the faceplate.

iii. 

Repeat step 

2

 

b

 as needed.

1

Extron

VOLUME

DISPLAY

ON

OFF

VIDEO

PC

MUTE

LAPTOP

Extron

VOLUME

DISPLAY

ON

OFF

LAPTOP

MUTE

PC

VIDEO

MLC 62 RS EU

MLC 62 RS MK

Rear Panel

Left Side Panel

RELAYS

N/O

 PWR

12 V

0.4 A max

 HOST/  

CONFIG

DIG

IT

AL

 IN

PU

T

+

Tx

Rx

1

Tx

Tx/

IR

1

2

C

1

2

R

PORT A

RS-232

PORT B

IR/ S

Peg

Peg

Slot

VOLUME

DISPLA

Y

PC

VIDE

O

OF

F

ON

MUTE

LAPTOP

MUTE

LAPTO

P

Pegs (2)

Button 
Membrane

Reviews: