Using the Wand 

It only takes a few minutes practice for you to become a whiz with a 
wand. 

Hold the wand in your hand like an ordinary pen or pencil, with your 
finger over the “press to read” switch.  For the best performance, you 
should hold the wand on a slight angle - about 10 to 20 degrees from 
straight up and down. 

When scanning a barcode, you should move your hand and forearm in 
the direction of the scan without twisting your wrist, so that the barcode 
wand won’t tilt from side to side - see the illustration below: 

Start with the wand tip in the white space at either end of the barcode, 
about a centimetre from the first bar.  The Z4 DataTraq is able to read 
barcodes whether they are scanned left to right or right to left.  The 
ideal scan path is indicated on the left below. 

Press the wand and scan the test barcode label on the right below, 
quickly and lightly.  A successful scan will be indicated by an audible 
“beep” - if there is no beep, you must try again. 

Ideal Wand Path (either direction)   

 

Test Barcode

 

 

Summary of Contents for Z4 DataTraq

Page 1: ...puters 456 North Road Ormond Victoria 3204 Australia Telephone 03 9578 7600 FAX 03 9578 7727 email solutions asp com au World Wide Web http www asp com au ASP Microcomputers is a division of Grayline...

Page 2: ......

Page 3: ...Care of your Z4 DataTraq 10 Printing Barcode Labels 10 What do I do if 11 Batteries 12 Technical Information 13 Barcode Types 16 ASCII Character Code Chart 17 Warranty 18 Year 2000 Statement 18 EMC St...

Page 4: ......

Page 5: ...to remember to charge the Z4 DataTraq s batteries this is automatic when the unit is connected to its Homebase Choice of scanners The Z4 DataTraq has been designed to support a wide variety of scanne...

Page 6: ...the back of the Homebase 4 Plug one end of the PC cable into the socket labelled COMPUTER on the back of the Homebase and the other end into the socket that you unplugged your keyboard from at the bac...

Page 7: ...232 cable from the back of your terminal and plug in the Y cable in its place Plug the RS 232 cable into the Y cable 4 Plug the other end of the Y cable into the socket labelled RS 232 on the back of...

Page 8: ...of the scan without twisting your wrist so that the barcode wand won t tilt from side to side see the illustration below Start with the wand tip in the white space at either end of the barcode about a...

Page 9: ...try to avoid using poor quality labels or inappropriate types of barcodes If in doubt discuss this with your dealer Try to guard against barcode damage such as Liquid spills on the barcode symbol coff...

Page 10: ...cond time to return the keypad to the normal unshifted state If you press the wrong shift key just press the other one to fix the problem The FUNC function key has two uses if you press it at the norm...

Page 11: ...press Echo option in Function 03 Use of the Comma Key The comma key can be used to delimit data fields Normally scanning a barcode representing A1000 followed by typing 10 ENTER on the keyboard would...

Page 12: ...ve downloaded the data to your computer you ll need to use this function to clear the storage memory Func 05 If you re having trouble transferring the data to your computer you may need to slow down...

Page 13: ...aTraq to factory default configuration 09 Sets or clears function access password 10 Displays amount of memory used and amount free 11 Downloads data stored in memory 12 Downloads stored barcode reads...

Page 14: ...ew inches Don t leave the unit in a hostile environment where it could be exposed to direct sunlight dust or dirt moisture or extremes of temperature Printing Barcode Labels If you need to print your...

Page 15: ...ddled with the settings on the Z4 DataTraq Make sure that Function 02 is set correctly and that suitable delays are set using Function 05 You ll probably have to call our service department for help w...

Page 16: ...use a single battery charge will last somewhere between those two figures When the Z4 DataTraq is used with ASP s Barcode Zapper CCD Scanner the 17 hour 100 continuous use figure above is reduced to a...

Page 17: ...e computer 3 Data into the BCR from the computer 4 CTS handshaking signal to the BCR 5 GROUND 6 Not connected 7 RTS handshaking signal from the BCR 8 RS 232 input from video terminal 9 Combined serial...

Page 18: ...d with a D25 Male connector is available on special order PC s with Non standard Keyboards Some PC s thankfully not many nowdays are not compatible with the IBM PC keyboard standard which means that t...

Page 19: ...always checks the CTS signal Clear To Send pin 4 before sending any data and if the CTS signal is turned off the BCR will not transmit the data Since this may cause problems with some applications the...

Page 20: ...de 128 consists of 106 different printed characters with each character having three possible meanings depending on which of three different character sets is in use EAN 128 is a specialised version o...

Page 21: ...Q 049 1 081 Q 113 Q 018 DC2 R 050 2 082 R 114 R 019 DC3 S 051 3 083 S 115 S 020 DC4 T 052 4 084 T 116 T 021 NAK U 053 5 085 U 117 U 022 SYN V 054 6 086 V 118 V 023 ETB W 055 7 087 W 119 W 024 CAN X 0...

Page 22: ...charges to your dealer location or ASP Units sent freight collect will not be accepted Freight back to you will be paid by ASP in the case of warranty repairs ASP welcomes suggestions for improvements...

Reviews: