NMG2
®
Stop-Time Measuring System
22
Version 3.0.0
www.asm-sensor.com
Pos : 44 /Bedienungs anl eitungen/NM G2/Pr ot okoll e/ Ges chw.mess ung
– Ei nzel mess ung @ 6\mod_1511339825069_78.doc x @ 49865 @ @ 1
Protocol Stop-Time Measurement – Single Measurement
→
0.
→
1.
→
2.
→
3.
→
4.
→
5.
→
6.
→
7.
0. Protocol ID (can be set by the customer, see chapter 4.2 Input of a Protocol ID (machine number) on
page 17).
1. Adjusted measurement start position
2. The velocity (independently of the sign), where standstill of the machine will be detected
3. Adjusted measuring direction
4. The max. velocity occurred after the start of measurement
5. The position where the highest velocity was achieved
6. The velocity at the start position
7. Adjusted start position
Pos : 45 /Bedienungs anl eitungen/NM G2/Pr ot okoll e/ Ges chw.mess - Aut om. Mess ung @ 6\ mod_1511340562376_78.doc x @ 49875 @ @ 1
Protocol: Stop-Time Measurement – Automatic Measurement
→
0.
→
1.
→
2.
→
3.
→
4. / 5. / 6.
0. Protocol ID (can be set by the customer, see chapter 4.2 Input of a Protocol ID (machine number) on
page 17).
1. Adjusted measurement start position
2. The velocity (independently of the sign), where standstill of the machine will be detected
3. Adjusted measuring direction
4. Max. velocity
5. Position of the max. velocity
6. Velocity at the start point
Pos : 46 /Bedienungs anl eitungen/NM G2/Berec hnung des Sic herheits abs tandes @ 6 \ mod_1510927108670_78. doc x @ 49622 @ 2 @ 1