4.4 Velocity Measurement
Steps 1 to 5: proceed as in the case of Stop-Time measuring
6.
Activate velocity measurement
Button [6] pressed: “
VELOCITY
” active
7.
Set the parameters for the velocity measurement
Button [8] is always
released during the velocity measurement, “
SINGLESHOT.
” active
Adjust the “
START POSITION
” (start of measurement) with the jog wheel [9]. The recommended value
is +2 mm for upward movement and -2 mm for downward movement.
8.
Activate the measuring mode
Now release the b
utton [1], “
TEST RUN
” is activated, 2 bars appear on the display, NMG2 is ready for
the measurement.
9.
Let the machine perform a complete cycle
10.
Read the measurement value
After the machine has stopped, press and release the button
ZERO
[5] to obtain the measurement
values. The max. velocity will be shown on the lower display
“MAX. VELOCITY”
[18] and the
corresponding position will appear on the upper display
“POSITION”
[17].
The printout shows the maximum speed between the start position and the complete standstill of the
machine. The actual speed in the start position also appears on the printout, so that the speed at each point
of the stroke can be determined by adjusting the start position.