Configuring the Unit via its Web Interface
Routing
ENC 1202
Version 1.0 Page
40
4.7.2 Routing > I/O
The “I/O” submenu is used to change the routing settings of the ENC 1202. The settings
are displayed and can be edited on the “Dante 1~8”, “Line” and “Mixer” tabs.
The structure is more or less the same for all tabs: each has 3 columns.
DESTINATION
Name and label of the output or SRC. If necessary, the label can be changed using the
“Label” (p. 36) parameter.
SOURCE
This column displays 2 drop-down menus where you can select the desired source for
each output.
The first drop-down menu allows you to narrow down the available source to the type
you are looking for. This filters the sources displayed in the second column according to
types—such as Mixer outputs.
The second drop-down menu allows you to choose the desired channel among the
selected source type(s).
TRANSPARENT
This setting is only available for “Dante” outputs.
Signals set to “Transparent” are not processed in any way (no delay, equalizer, etc.): they
are transmitted to the corresponding output without change.