Configuring the Unit via its Web Interface
Receivers (Inputs)
ENC 1202
Version 1.0 Page
29
4.5 Receivers (Inputs)
The “Receivers” menu allows you to view and edit all of the ENC 1202’s inputs. The drop-
down menu is used to navigate the following 3 panes: General, Metering and Labels.
4.5.1 Receivers (Inputs) > General
The “General” pane is where you can edit basic settings for the 4 line inputs provided on
the ENC 1202’s rear panel (via one RJ45 socket). The corresponding parameters are dis-
played on the “Line 1–2” and “Line 3–4” tabs.
All Line inputs provide the same parameters.
Line 1–2, Line 3–4
Options
Click the buttons in this row to activate or switch off the corresponding functions. Active
functions are displayed on an orange background.
Mute
Clicking [Mute] (orange) will switch that channel off.
Phase
Clicking [Phase] (orange) will invert the signal phase (180°).
EQ
All of the ENC 1202’s physical inputs are equipped with an equalizer. This is
where you can activate it (orange) or switch it off.
See “EQ” (p. 30) for a detailed discussion of the equalizer.
Edit EQ
[Edit EQ] is always displayed in orange. Clicking this button opens a pop-up win-
dow where you can set the equalizer. See “EQ”.
Trim
This fader icon can be used to lower the channel’s signal level by up to 91dB, or to boost
it by up to 24dB. The fader only allows you to change the level in steps of 1dB. Use the
value field to the right for more precise settings (in steps of 0.1dB).
Double-click the fader to set it to the minimum value. Hold down the Shift key while
double-clicking the fader to reset the fader to the default value.