Configuring the Unit via its Web Interface
Transmitters (Outputs)
ENC 1202
Version 1.0 Page
35
Double-click the fader to set it to the minimum value. Hold down the Shift key while dou-
ble-clicking the fader to reset the fader to the default value.
Note:
• In Transparent mode, “Trim” and “Delay” are not displayed, because these functions are
bypassed.
Full Scale Reference
This fader allows you to set the analog reference level for 0dBFS. See also “Full Scale Ref-
erence” on page 30 for details. This setting affects the read-out of the Peak Level meter
below this fader.
The setting range for this parameter is –15dBu~+24dBu. Hold down the Shift key while
double-clicking the fader to reset the fader to 0dBu. Double-click the fader to set it to the
minimum value.
Delay
The Delay fader allows you to set the desired signal delay (0~2.7 seconds or the equiva-
lent in meters or feet).
Peak Level
The “Peak Level (L)” and “Peak Level (R)” meters show the peak levels of the left and right
channels.
The audio signal’s current level is displayed in orange on a scale between –∞dBFS (corre-
sponds to –126dBFS) and 0dBFS.
4.6.2 Transmitters (Outputs) > Metering
The “Metering” submenu shows the levels of the ENC 1202’s outputs.
Use the tabs to switch between the “Dante 1–8” and “Line 1–8” groups.
The tabs allow you to view the levels (–126dBFS~0dBFS) of the corresponding output
channels. If necessary, the levels of the line outputs can be changed using the “Trim”