![ASEA AC100Q-3 Operation Manual Download Page 42](http://html1.mh-extra.com/html/asea/ac100q-3/ac100q-3_operation-manual_2981668042.webp)
AC100Q-3 Operations Manual....
42
SHORE CORD SETUP CONV.CAPACITY:100.0kVA
MASTER CORD CAPACITY: 150 Amps
VOLTAGE: 400 Vac, FORM: 3
Ø
, Freq.: 50Hz
More Less Exit
7.3
LOAD MANAGEMENT OPERATION, cont.
7.3.2 Shore Cord Setup
, Single, Master, or Slave Converters
The Shore Cord Setup screen is used to set the actual shore cord ampacity based on the marina’s
dock or pedestal circuit breaker. The converter’s new, programmed CONV. CAPACITY is then
displayed for reference. The converter’s Load Level and Power indicators for Shore Power and
Converter Power will then display the actual converter capacity usage based on the programmed
CONV. CAPACITY.
It is important to understand that this is an indication device, and affects reporting and alarming
only. The peak and average overload capabilities are not affected by this setting. Dynamic
response to loading and equipment startup surges is unaffected. The intent here is to prevent
tripping of dockside circuit breakers by average loading when a smaller than desired shore supply
is used.
From the front panel, press the
SHORE POWER
+
F2
buttons, and then Cord (
F1
) to access the
following screen:
Press More (
F1
) or Less (
F2
) to adjust the MASTER CORD CAPACITY, and Exit (
F5
) to save
the settings and exit the screen.
Default
Range
Units
CONV. CAPACITY true capacity based on cord capacity, voltage, and form
kVA
CORD CAPACITY 250
30, 32, 50, 60, 63, 100, 125, 150, 200, 250 Amps
The CONV. CAPACITY is calculated as:
V
L-L
A
3
and is never greater than the
converter’s actual rating if the shore supply size has a greater capacity than the converter.
Summary of Contents for AC100Q-3
Page 15: ...AC100Q 3 Operations Manual 15 5 1 MECHANICAL INSTALLATION cont FIGURE 2 MECHANICAL OUTLINE ...
Page 16: ...AC100Q 3 Operations Manual 16 5 1 MECHANICAL INSTALLATION cont FIGURE 3 MECHANICAL OUTLINE ...
Page 38: ...AC100Q 3 Operations Manual 38 This page intentionally left blank ...
Page 55: ...AC100Q 3 Operations Manual 55 FIGURE 8 STATUS WORD BIT DEFINITIONS ...