background image

 

 
 
 
 
 
 
 
 
 
 

 

Vertikale kühlvitrinen 

 
 

 

 

 

 
 
 

Kühlschränke und tiefkühlschränke 

 

 

 

ALLGEMEINE GEBRAUCHSANWEISUNGEN  

 

 

 

 

Cod. 26.23.073 
Rev. 6 

 

Ihr Nordcap Fachhändler:

Kälte-Berlin
Am Pfarracker 41
12209 Berlin
Fon: +49 30 74 10 40 22
Fax: +49 30 74 10 40 21
Mail: [email protected]
Internet: www.kaelte-berlin.com

Summary of Contents for Y39E

Page 1: ...tiefk hlschr nke ALLGEMEINE GEBRAUCHSANWEISUNGEN Cod 26 23 073 Rev 6 Ihr Nordcap Fachh ndler K lte Berlin Am Pfarracker 41 12209 Berlin Fon 49 30 74 10 40 22 Fax 49 30 74 10 40 21 Mail info kaelte be...

Page 2: ...ANICAL MOUNTING 3 3 ELECTRICAL CONNECTIONS 3 4 ELECTRICAL WIRING DIAGRAM 4 FUNCTIONS 4 1 ON STAND BY FUNCTION 4 2 NORMAL MODE AND ECONOMIC MODE 4 3 MEASURING AND VISUALIZATION 4 4 DIGITAL INPUT 4 5 OU...

Page 3: ...Indicates AUX output status on on off off or inhibited flashing 12 Led Stand By Indicate the Stand by status 2 PROGRAMMING 2 1 FAST PROGRAMMING OF SET POINT Press the key P then release it and the di...

Page 4: ...any key for the time t Lo the instrument automatically disable the normal functions of the keys When the keyboard is lock if any of the key is pushed on the display will appear Ln to indicate the act...

Page 5: ...input configured as i Fi 1 2 or 3 If i Et oF the selection mode Eco Norm through the digital input is disabled The economic mode activated is indicated by the label Eco If i dS Ec the display in econ...

Page 6: ...o3 The outputs can be configured for the following functions ot to control the compressor or however the temperature control device dF to control the defrosting device Fn to control the fans Au to co...

Page 7: ...ble to prevent activation of the output after the instrument is turned on for the time set in the parameter P od During the power on delay phase the display shows the indication od alternating with th...

Page 8: ...s interrupted If the temperature measured by the probe is higher than the temperature set in the parameter d tE the defrosting is inhibited The active defrost is shown on the instrument display with t...

Page 9: ...but with an inverse function output activated in normal condition and disabled in alarm status L when one wants the function described as AL but with inverse logic output activated in normal conditio...

Page 10: ...eters To use the device A01 it s necessary that the device or instrument are being supplied SUPPLY USB SUPPLY ADAPTER 12 VDC AC SUPPLY USB For additional info please have a look at the A01 instruction...

Page 11: ...mode H Heating C Cooling nr Neutral Zone H C nr C d parameters relative to defrosting control 21 d dt Defrosting Type EL Electrical heating stop compr in hot gas reverse cycle EL in EL 22 d di Defros...

Page 12: ...AL t L on HE dF 52 o o3 OUT3 function see o o1 oF ot dF Fn Au At AL t L on HE Fn 53 o bu Buzzer function mode oF disable oF 1 2 3 3 1 active alarms only 2 key pressed only 3 active alarms and key pres...

Page 13: ...up to 3 relay outputs OUT1 SPST NO 16A AC1 6A AC3 1HP 250VAC 1 2HP 125 VAC OUT2 SPDT 8A AC1 3A AC3 1 2HP 250VAC 1 3HP 125 VAC OUT3 SPST NO 5A AC1 2A AC3 250 VAC 1 8HP 125 250VAC 16 A Max for common pi...

Page 14: ...2KV com mode 1 KV diff mode EN61000 4 6 3V LV 2006 95 CE EN 60730 1 EN 60730 2 7 EN 60730 2 9 Directive 37 2005 CE EN13485 air S A 2 50 C 90 C with probe NTC 103AT11 7 5 INSTRUMENT ORDERING CODE Y39E...

Page 15: ...iegend transportiert worden sollte es erst nach 24 Stunden in Betrieb genommen werden damit das Oel wieder in den Kompressor zur ckfliessen kann Der Schrank muss ber das beiliegende Netzkabel an eine...

Page 16: ...ng flexibel F r diese Arbeit keine spitzen oder scharfe Gegenst nde benutzen welche die T rdichtung besch digen k nnten Achtung Folgende Arbeit muss von einem Servicetechniker ausgef hrt werden Schalt...

Page 17: ...schrauben IST DAS SPEISEKABEL BESCH DIGT MUSS DIESES VOM HERSTELLER BZW SEINEM KUNDENDIENST ODER AUF JEDEM FALL VON EINER QUALIFIZIERTEN PERSON ERSETZT WERDEN UM RISIKEN ZU VERMEIDEN 7 L N G E R E Z E...

Reviews: