ASCON TECNOLOGIC - Y39E 

 

- OPERATING INSTRUCTIONS - Vr. Mondial Group - 10/10 -  ISTR-MY39EENGmondial -  PAG. 2

 

device,  an  auxiliary  device  or  an  alarm.  The  2  inputs  for 
temperature  probes  can  be  used  to  measure  the  control 
temperature,  the  evaporator  temperature,  products  or  aux 
temperature,    while  the  digital  input  can  be  programmed  to  carry 
out  various  functions  such  as  door  opened  signal,  defrosting 
commands,  selecting  a  different  set  of  temperature  regulations, 
external alarm signals, activating a continuous cycle, and activating 
an auxiliary output etc.  
 

1.2 - FRONT PANEL DESCRIPTION

 

6

7

12

8

3

1

5

2

4

9

Aux

10

11

 

1  -  Key  P

  :  Used  for setting the Set point (press and release) and 

for programming the function parameters

 

(hold pressed for 5 sec.)

 

In programming mode is used to enter in parameters edit mode and 
confirm  the  values.  In  programming  mode  it  can  be  used  together 
with  the  UP  key  to  change  the  programming  level  of  the 
parameters. 
When the keyboard is locked  it can be used together with the UP 
(hold pressed for 5 sec.)  key to unlock the keyboard. 

2 - Key DOWN/Aux

 : In programming mode is used for decreasing 

the  values  to  be  set  and  for  selecting  the  parameters.

 

In  normal 

mode  it  can  also  be  programmed  via  the  parameter “t.Fb” to carry 
out other functions (hold  pressed for 1 sec.) such as activating the 
Aux output, starting up the continuous cycle, etc. (see functions of 
keys U and Down).

 

3  -  Key  UP/DEFROST

  : In normal mode can be used to start/stop 

manual defrosting (hold  pressed for 5 sec.). In programming mode 
is  used  for  increasing  the  values  to  be  set  and  for  selecting  the 
parameters.

 

In programming mode can be used  togetherwith key P 

to  change  parameters  level.  Pressed  together with the key P for 5 
sec. allow the keyboard unlock 

4 - Key U : 

Used (press and release) for visualising the instrument 

variables (measured temperatures etc.). In programming mode can 
be used to come back in normal mode (hold for 2 sec.). In normal 
mode it can also be programmed via the parameter “t.UF” to carry 
out  other  functions  (hold    pressed  for  1  sec.)  such  as  turning  on 
and off (stand-by) the device, activating the Aux output, starting up 
the continuous cycle, etc. (see functions of keys U and Down).

 

5  -  Led  SET 

:  In  normal  mode  it  serves  to  indicate  when  a  key  is 

pressed. In programming mode indicates the programming level of 
the parameters. 

6  -  Led  OUT  -  COOL 

:  Indicates  the output status (compressor or 

temperature  control device) when the istrument is programmed for 
cooling operation; on (on), off (off) or inhibited (flashing). 

7  -  Led  OUT  -  HEAT 

:  Indicates  the  output  status  (compressor  or 

temperature  control device) when the istrument is programmed for 
heating operation; on (on), off (off) or inhibited (flashing). 

8  -  Led  DEFROST  :

  Indicates  defrosting  in  progress  (on)  or 

drainage time in progress (flashing)  

 

9  -  Led  FAN  :

  Indicates  fan  output  status  on  (on),  off  (off)  or 

delayed after defrosting (flashing) 

10  -  Led  ALARM

  :  Indicates  the  alarm  status  (on),  off    (off)  and 

silenced or memorized (flashing) 

11  -  Led  AUX

  :  Indicates  AUX  output  status  on  (on),  off  (off)  or 

inhibited (flashing) 

12 - Led Stand-By:

 Indicate the Stand-by status.

 

 

2 -  PROGRAMMING 

 
2.1 -

 

FAST PROGRAMMING OF SET POINT

 

Press  the  key  P  then  release  it  and  the  display  will  show

 “SP

” (or 

“SPE”

) alternating with the set value. 

To  change  it  press  the  UP  key  to  increase  the  value  or  DOWN  to 
decrease it.  

These keys increase or decrease the value one digit at a time, but 
if  the  button  is  pressed  for  more  than  one  second  the  value 
increase  or  decreases rapidly, and after two seconds pressed, the 
speed increases even more to all the desired valued to be reached 
rapidly. 
However, through par.

 "t.Ed”

 is possible to determine whether and 

which Sets are set with the fast mode bybutton P. 
The  parameter  is  programmable  with    a  value  between  oF  and  4 
which means that: 
oF = Nothing is set with the key P  (the P pressed and released has 
no effect) 
1 = can be adjusted only SP (normal) 
2 = can be adjusted only SPE (economic) 
3 = can be adjusted both SP and SPE 
4 = can be adjusted the active set (SP or or SPE) 
For  example,  if  the  parameter  "t.Ed"  =  1  or  3,  the  procedure  is  as 
follows: 
Press key P then release it and the display will show 

"SP"

 alternate 

value. 
To  modify  press  key  UP  or  DOWN  to  increase  the  value  to 
decrease. 
If there is only the Set Point 1 ("t.Ed" = 1) once the desired value by 
pressing the P button to exit the Set programming mode. 
If  is  also  programmable  the  EconomicSet  Point  ("t.Ed"  =  3)  by 
pressing and releasing the P key again the display will show 

"SPE"

 

alternate to the set value. 
To modify press key UP or DOWN like Set “SP”. 
When    the  desired  value  is  set  press  the  key  P  to  exit  from  Set 
Point programming mode. 
Exiting  the  Set  mode  is  achieved  by  pressing  the  P  key  or 
automatically  if  no  key  is  pressed  for  10  seconds.  After  that  time 
the display returns to the normal function mode. 
 

2.2 - STANDARD MODE  PARAMETERS PROGRAMMING

 

To  access  the  instrument’s  function  parameters  when  password 
protection is disable, press the key 

P

 and keep it pressed for about 

5  seconds,  after  which  the  display  will  visualised  the  code  that 
identifies the first parameter.  
Using  the  UP  and  DOWN  keys,  the  desired  parameter  can  be 
selected  and  pressing  the  P  key,  the  display  will  alternately  show 
the parameter code and its setting that can be changed with the UP 
and DOWN  keys. 
Once  the  desired  value  has  been  set,  press  the  key  P  again:  the 
new  value  will  be  memorised  and  the  display  will  show  only  the 
code of the selected parameter.  
Pressing  the  UP and DOWN  keys, it is possible to select another 
parameter and change it as described.  
To exit the programming mode, do not press any key for about 30 
seconds,  or  keep  the  U  key  pressed  for  2  sec.  until  it  exits  the 
programming mode. 

2   s e c .

H o ld   f o r

H o ld   f o r

5   s e c .

 

 
2.3 - PARAMETER PROTECTION USING THE PASSWORD 

The  instrument  has  a  parameter  protection  function  using  a 
password that can be personalised, through the  

“t.PP”

 parameter. 

If  one  wishes  to  have  this  protection,  set  the  password  number 
desired  in  the  parameter  “t.PP”.  When  the  protection  is  activate, 
press  the  P  key  to  access  the  parameters  and  keep  it  press  for 
about 5 seconds, after which the display will show 

“r.P”

 . 

Summary of Contents for Y39E

Page 1: ...tiefk hlschr nke ALLGEMEINE GEBRAUCHSANWEISUNGEN Cod 26 23 073 Rev 6 Ihr Nordcap Fachh ndler K lte Berlin Am Pfarracker 41 12209 Berlin Fon 49 30 74 10 40 22 Fax 49 30 74 10 40 21 Mail info kaelte be...

Page 2: ...ANICAL MOUNTING 3 3 ELECTRICAL CONNECTIONS 3 4 ELECTRICAL WIRING DIAGRAM 4 FUNCTIONS 4 1 ON STAND BY FUNCTION 4 2 NORMAL MODE AND ECONOMIC MODE 4 3 MEASURING AND VISUALIZATION 4 4 DIGITAL INPUT 4 5 OU...

Page 3: ...Indicates AUX output status on on off off or inhibited flashing 12 Led Stand By Indicate the Stand by status 2 PROGRAMMING 2 1 FAST PROGRAMMING OF SET POINT Press the key P then release it and the di...

Page 4: ...any key for the time t Lo the instrument automatically disable the normal functions of the keys When the keyboard is lock if any of the key is pushed on the display will appear Ln to indicate the act...

Page 5: ...input configured as i Fi 1 2 or 3 If i Et oF the selection mode Eco Norm through the digital input is disabled The economic mode activated is indicated by the label Eco If i dS Ec the display in econ...

Page 6: ...o3 The outputs can be configured for the following functions ot to control the compressor or however the temperature control device dF to control the defrosting device Fn to control the fans Au to co...

Page 7: ...ble to prevent activation of the output after the instrument is turned on for the time set in the parameter P od During the power on delay phase the display shows the indication od alternating with th...

Page 8: ...s interrupted If the temperature measured by the probe is higher than the temperature set in the parameter d tE the defrosting is inhibited The active defrost is shown on the instrument display with t...

Page 9: ...but with an inverse function output activated in normal condition and disabled in alarm status L when one wants the function described as AL but with inverse logic output activated in normal conditio...

Page 10: ...eters To use the device A01 it s necessary that the device or instrument are being supplied SUPPLY USB SUPPLY ADAPTER 12 VDC AC SUPPLY USB For additional info please have a look at the A01 instruction...

Page 11: ...mode H Heating C Cooling nr Neutral Zone H C nr C d parameters relative to defrosting control 21 d dt Defrosting Type EL Electrical heating stop compr in hot gas reverse cycle EL in EL 22 d di Defros...

Page 12: ...AL t L on HE dF 52 o o3 OUT3 function see o o1 oF ot dF Fn Au At AL t L on HE Fn 53 o bu Buzzer function mode oF disable oF 1 2 3 3 1 active alarms only 2 key pressed only 3 active alarms and key pres...

Page 13: ...up to 3 relay outputs OUT1 SPST NO 16A AC1 6A AC3 1HP 250VAC 1 2HP 125 VAC OUT2 SPDT 8A AC1 3A AC3 1 2HP 250VAC 1 3HP 125 VAC OUT3 SPST NO 5A AC1 2A AC3 250 VAC 1 8HP 125 250VAC 16 A Max for common pi...

Page 14: ...2KV com mode 1 KV diff mode EN61000 4 6 3V LV 2006 95 CE EN 60730 1 EN 60730 2 7 EN 60730 2 9 Directive 37 2005 CE EN13485 air S A 2 50 C 90 C with probe NTC 103AT11 7 5 INSTRUMENT ORDERING CODE Y39E...

Page 15: ...iegend transportiert worden sollte es erst nach 24 Stunden in Betrieb genommen werden damit das Oel wieder in den Kompressor zur ckfliessen kann Der Schrank muss ber das beiliegende Netzkabel an eine...

Page 16: ...ng flexibel F r diese Arbeit keine spitzen oder scharfe Gegenst nde benutzen welche die T rdichtung besch digen k nnten Achtung Folgende Arbeit muss von einem Servicetechniker ausgef hrt werden Schalt...

Page 17: ...schrauben IST DAS SPEISEKABEL BESCH DIGT MUSS DIESES VOM HERSTELLER BZW SEINEM KUNDENDIENST ODER AUF JEDEM FALL VON EINER QUALIFIZIERTEN PERSON ERSETZT WERDEN UM RISIKEN ZU VERMEIDEN 7 L N G E R E Z E...

Reviews: