Ascon Tecnologic - T82N- OPERATING INSTRUCTIONS - PAG. 4

i.Fct

 = 

4

 - 

Monostable Reset-Start/Stop

Activating the 

CNT

 input and keeping it active, the timer 

resets and starts counting, disabling the 

CNT 

input the 

count stops disabling the output if active.
This operating mode is similar to the one of the tradition-
al timers in which counting is enabled when the instru-
ment is powered while the 

Reset

 occurs when power 

supply is removed.

CNT

Count

RESET

0 . 1 . 2 . 3

i.fct

 = 

4

Reset/

Start

Reset/

Start

Stop

0 . 1 . 2 . 3

0 . 1 . 2 . 3

0

Stop

Reset

i.Fct

 = 

5

 - 

Reset/Start/Stop

At 1

st

 

CNT

 impulse the timer is reset, at the 2

nd

 the count 

starts, at the 3

rd

 impulse the count stops disabling the 

output if active and so on.

CNT

Count

RESET

0 . 1 . 2 . 3

0

0

0 . 1 . 2 . 3 . 4 .   0

i.fct

 = 

5

Start

Reset

Reset

Stop

Start

Stop/

Reset

i.Fct

 = 

6

 - 

Bistable Start/Stop-Reset

At 1

st

 

CNT

 impulse the count is started, while at the 2

nd

 

impulse, if given before the end of the count, the count is 
stopped disabling the output if active and reset, other-
wise, if the 2

nd

 impulse should arrive after the end of the 

count it starts directly a new cycle.

CNT

Count

RESET

0 . 1 . 2 . 3 . 0

0 . 1 . 2 . 3 . 4 . 0

0 . 1 . 2 . 0

i.fct

 = 

6

Start

Stop

Reset

Start Stop

Reset

Start

End

Reset

5.2 

Out1 Operating mode

The Output 1 operation can be programmed in 

6 different 

modes

 with 

F.o1t

 parameter:

F.o1t

 = 

1

 - 

ON DELAY

Received the 

Start

 signal, instrument starts counting and, 

at the end of 

S.t1

 time, activates the 

Out1

 output.  The 

output is disabled by the 

Reset

 signal.

Reset

OUT1

Start

off

off

S.t1

f.o1t

 = 

1

F.o1t

 = 

2

 - 

Feed-through

Received the 

Start

 signal, the instrument starts counting 

and activates the 

Out1

 output; 

Out1 is disabled 

when 

S.t1

 time has elapsed.  The output can be reactivated 

only after a 

Reset

 and a new 

Start

 signal.

Reset

OUT1

Start

off

f.o1t

 = 

2

S.t1

F.o1t

 = 

3

 - 

Asymmetrical oscillator with start ON

This operating mode requires the setting of both 

S.t1

 

and 

S.t2

 Set times.

Received the 

Start

 signal, 

Out1

 is enabled for the 

S.t1

 time 

then disabled, reactivated when 

S.t2

 time has elapsed and 

so on until the 

Stop

/

Reset

 signal is detected.

S.t1

Out1 ON time

S.t2

Out1 OFF time

.

Reset

OUT1

Start

off

f.o1t

 = 

3

S.t1

S.t1

S.t2

S.t1

S.t2

F.o1t

 = 

4

 - 

Asymmetrical oscillator with start OFF

This operating mode implies the setting of both 

S.t1

 and 

S.t2

 Set times.

Received the 

Start

 signal, 

Out1

 remains disabled for the 

S.t1

 time then is activated for the time set at 

S.t2

 and so 

on until the 

Stop

/

Reset

 signal is detected.

S.t1

Out1 OFF time

S.t2

Out1 ON time

.

Reset

OUT1

Start

off

off

off

off

f.o1t

 = 

4

S.t2

S.t2

S.t1

S.t1

S.t1

F.o1t

 = 

5

 - 

Asymmetrical oscillator with start OFF 1 cycle

This operating mode operates as 

f.o1t

 = 

4

 but executes 

only 1 Start/Pause

 cycle.

Received the 

Start

 signal, 

Out1

 remains disabled for the 

S.t1

 time then is activated for the time set at 

S.t2

.

The cycle can be repeated only after a 

Reset

 signal and 

a new 

Start

 command.

Reset

OUT1

Start

off

off

S.t1

S.t2

f.o1t

 = 

5

F.o1t

 = 

6

 - 

Delay in lack of excitation (or delay in  

de-excitation)

On the rising edge of the 

CNT

 input

 Start signal

Out1

 

is 

energized

.  When the 

CNT

 signal 

is removed

Out1 re-

mains energized

 and 

starts the 

S.t1

 count

 elapsed which 

Out1 is de-energized

.  If, during the 

S.t1 

count, a signal 

is detected on the 

CNT

 input, the 

time is reset

 and 

will be 

restarted

 when 

signal ceases

.

Note: 

This functioning mode operates in this way 

regard-

less

 the 

i.Fct

 parameter setting.  

Out2

 output (if 

used) in this operating mode 

can only operate

 in 

F.o2t

 = 

1

 or 

2

 modes.  In 

F.o2t

 = 

2

 mode 

OUT2

 

output is activated when the 

CNT

 input is enabled and 

then deactivated when 

CNT

 input is disabled.

CNT

OUT1

off

off

off

f.o1t

 = 

6

S.t1

S.t1

S.t1

Summary of Contents for T82N

Page 1: ...FC communication interface embedded in the instrument The instrument offers the possibility to program up to 3 delay times or Set Times 6 operating modes for Out1 output 10 operating modes for Out2 ou...

Page 2: ...ent for applications not expressly permitted by the above mentioned rule must adopt all the necessary protective measures The instrument must not be used in dangerous environ ments flammable or explos...

Page 3: ...NC NO C NC C NO Voltage inputs 24 240 VAC VDC 24 240 VAC VDC 5 OPERATING MODE 5 1 Counting commands operation Counting is enabled and disabled using the the digital inputs CNT and RST The operating mo...

Page 4: ...Reset and a new Start signal Reset OUT1 Start off f o1t 2 S t1 F o1t 3 Asymmetrical oscillator with start ON This operating mode requires the setting of both S t1 and S t2 Set times Received the Star...

Page 5: ...t f o1t 3 f o2t 3 OUT1 off off S t1 S t1 S t2 OUT2 off off S t3 S t3 Reset Start f o1t 4 f o2t 3 OUT1 off S t2 S t1 OUT2 off off off off off S t3 S t2 S t1 S t3 Reset Start f o1t 5 f o2t 3 OUT1 S t2 S...

Page 6: ...Out1 but with an S t3 interme diate settable dead time Also in this case this function is intended to be used with F o1t 3 or 4 only oscillator mode functioning in order to obtain the alternated opera...

Page 7: ...TOP 5 Bistable RESET START STOP 6 Bistable START STOP RESET 4 8 F o1t OUT1 output operating mode 1 On delay 2 Feed through 3 Asymmetrical oscillator with start ON 4 Asymmetrical oscillator with start...

Page 8: ...tput Electrical life 100000 operations Overvoltage category II Protection class Class II Insulation Reinforced insulation between low voltage parts power supply and relay outputs and front panel Main...