Ascon Tecnologic - T82N- OPERATING INSTRUCTIONS - PAG. 2
2. PROGRAMMING
2.1
Parameters configuration with AFC1
The instrument can be programmed through the enbedded
NFC
communication interface.
The transmission of the parameters configuration to the in-
strument then takes place via the
AFC1
device and a
PC
with
the
AT Universal Config
configuration software
or
via the
NFC
interface of a
smartphone
with the dedicated
ATConf
APP.
To configure the instrument with the
NFC
, it is not necessary
to power the timer, but simply put its front panel on the sym-
bol
of the
AFC1
device surface (which is powered directly
by the
USB
port connected to the
PC
) or on the part of the
smartphone where the
NFC
interface is located (for this con-
sult the smartphone user manual) then send the parameters
to the instrument’s memory.
USB
USB
A
F
C
1
N
F
C
3. USAGE WARNINGS
3.1
Allowed Usage
D
The instrument has been projected as measure and
control device, built according to EN61812-1 for the
altitudes operation below 2000 ms.
Using the instrument for applications not expressly permitted
by the above mentioned rule must adopt all the necessary
protective measures.
The instrument
must not be used in dangerous environ-
ments
(flammable or explosive) without adequate protections.
D
The installer must ensure that the EMC rules are
respected, also after the instrument installation, if
necessary using proper filters.
4. INSTALLATION WARNINGS
4.1
Mechanical Mounting
The instrument is designed for mounting inside a switch-
board with fixing on a standard DIN guide.
Avoid placing the instrument in environments with very high
levels of humidity that may create condensation or dirt that
could lead to the introduction of conductive parts or substanc-
es into the instrument.
Ensure adequate ventilation to the instrument and avoid
installation in containers that house devices which may
overheat or which may cause the instrument to function at a
temperature higher than the one permitted and declared.
Connect the instrument as far away as possible from sourc-
es of electromagnetic disturbances such as motors, power
relays, relays, solenoid valves, etc..
4.2
Mechanical dimensions
[mm]
4.2.1
Instrument dimensions
CN/CNT
OUT1
OUT2
6
10
9
8
7
5
4
3
2
1
nfc
34
49
73
35
90