Ascon Tecnologic - T82N- OPERATING INSTRUCTIONS - PAG. 6
F.o2t
=
6 - Activation at
S.t1
count end with
S.t3
delay for
S.t2
time
Out2
thus configured is activated, as for
F.o2t
=
5
, when
S.t1
count has elapsed for the time
S.t2
but with a settable
delay
S.t3
. This function is intended to be used with
F.o1t
=
2
only.
Reset
Start
f.o1t
=
2
,
f.o2t
=
6
OUT1
off
S.t1
OUT2
off
off
S.t3 S.t2
F.o2t
=
7 - Activation at the end of
S.t1
count with delay
S.t2
Out2
thus configured is activated when
S.t1
count has
elapsed with a settable delay
S.t2
. This function is in-
tended to be used with
F.o1t
=
2
only and can be used to
create a
star-delta starter
where the time
S.t1
is the
Star
operating time
while
S.t2
is
the Star-Delta transfer time
.
Reset
Start
f.o1t
=
2
,
f.o2t
=
7
OUT1
off
OUT2
off
off
S.t1
S.t2
F.o2t
=
8 - Counting operation negated with respect to Out1
Out2
output thus configured is activated, during the count,
with the opposite logic to
Out1
. This function is intended to
be used with
F.o1t
=
3
or
4
only (oscillator mode functioning)
in order to obtain the alternated operation of the two outputs.
Reset
OUT1
Start
off
S.t1
S.t1
S.t2
S.t2
S.t1
OUT2
off
off
off
f.o1t
=
3
,
f.o2t
=
8
off
off
off
Reset
OUT1
Start
S.t1
S.t1
S.t1
S.t2
S.t2
OUT2
off
off
off
off
f.o1t
=
4
,
f.o2t
=
8
off
off
off
F.o2t
=
9 - Counting operation negated with respect to Out1
but with an
S.t3
dead time
As in
F.o2t
=
8
, while counting
Out2
output is activated
with the opposite logic to
Out1
, but with an
S.t3
interme-
diate settable dead time.
Also in this case, this function is intended to be used with
F.o1t
=
3
or
4
only (oscillator mode functioning) in order
to obtain the alternated operation of the two outputs, but
with a dead time between the activations.
Reset
OUT1
Start
off
S.t1 S.t3
OUT2
off
off
f.o1t
=
3
,
f.o2t
=
9
off
off
off
S.t2 S.t3
S.t1 S.t3
S.t1
S.t3
S.t2 S.t3
Reset
OUT1
Start
off
S.t1 S.t3
OUT2
off
off
f.o1t
=
4
,
f.o2t
=
9
off
off
off
S.t2 S.t3
S.t1 S.t3
S.t1
S.t3
S.t2 S.t3
F.o2t
=
10 - Symmetrical denied operation with respect
to Out1 with dead time
S.t3
As in
F.o2t
=
9
mode, while counting
Out2
output is
activated with the opposite logic to
Out1
, with an
S.t3
intermediate settable dead time, but with the same active
time of
S.t1
.
Also in this case, this function is intended to be used with
F.o1t
=
3
or
4
only (oscillator mode functioning) in order
to obtain the alternated operation of the two outputs with
a dead time between the activations, but with the pos-
sibility to establish the total duration of the cycle through
the time
S.t2
(for example for a washing, cleaning, pol-
ishing or similar treatment cycle).
Note:
The total time is established to be
S.t2
as it has an
independent time scale with respect to
S.t1
and
S.t3
which have the same time scale. For these applica-
tions
S.t2
probably needs to be set
in hours
while
S.t1
and
S.t3
could be
in minutes
.
Reset
OUT1
Start
off
S.t1 S.t3
OUT2
off
f.o1t
=
3
,
f.o2t
=
10
off
S.t3
S.t1
S.t1
S.t1
S.t3
S.t3 S.t1
S.t1
S.t2
S.t2
off
Reset
OUT1
Start
off
S.t1 S.t3
OUT2
off
f.o1t
=
4
,
f.o2t
=
10
off
S.t3
S.t1
S.t1
S.t1
S.t3
S.t3 S.t1
S.t1
S.t2
S.t2
off
off
off
off