9.  error messAges

9.1  out oF rAnge signAls

The upper display shows the OVER-RANGE and UNDER-
RANGE conditions with the following indications:
Over-range  

 

Under-range

  

The sensor break will be signalled as an out of range 

note: 

When an over-range or an under-range is detected, 
the alarms operate as in presence of the maximum or 
the minimum measurable value respectively.

To check the out of span Error condition, proceed as follows:

1. 

Check the input signal source and the connecting line.

2. 

Make sure that the input signal is in accordance with the 
instrument configuration. 
Otherwise, modify the input configuration (see section 4).

3. 

If no error is detected, send the instrument to your 
supplier to be checked.

9.2  list oF possible errors

ErAT

  Fast Auto-tune cannot start.  The measure value is 

too close to the set point.  Press the 

 button in 

order to delete the error message.

NoAt

  Auto-tune not finished within 12 hours.

ErEP

  Possible problem in the instrument memory. 

The message should automatically disappear, if the 
error persists, send the instrument to your supplier.

RonE

  Possible problem of the firmware memory. 

If this error is detected, send the instrument to your 
supplier.

Errt

  Possible problem of the calibration memory. 

If this error is detected, send the instrument to your 
supplier.

E.P.rE

  Potentiometer reversed. 

The message disappears as soon as the button 

 is 

pressed (the instrument returns to the 

P.cAL

 parameter).

no.Pt

  No potentiometer error. 

The message disappears as soon as the button 

 is 

pressed (the instrument returns to the 

P.cAL

 parameter).

E.P.cA

  Potentiometer calibration error. 

The message disappears as soon as the button 

 is 

pressed (the instrument returns to the 

P.cAL

 parameter).

10.  generAl notes

10.1 proper use

Every possible use not described in this manual must be 
consider as a improper use.
This instrument is in compliance with 

EN 61010-1 “Safety 

requirements for electrical equipment for measurement, 
control and laboratory use”; for this reason it could not be 
used as a safety equipment.
Whenever a failure or a malfunction of the control device 
may cause dangerous situations for persons, thing or 
animals, please remember that the plant has to be equipped 
with additional safety devices.

Ascon Tecnologic S.r.l. and its legal representatives do not 
assume any responsibility for any damage to people, things 
or animals deriving from violation, wrong or improper use or 
in any case not in compliance with the instrument’s features.

10.2 wArrAnty

This product is under warranty against manufacturing 
defects or faulty materials that are found within 18 months 
from delivery date. The warranty is limited to repairs or to the 
replacement of the instrument.
The tampering of the instrument or an improper use of the 
product will bring about the immediate withdrawal of the 
warranty effects.
In the event of a faulty instrument, either within the period 
of warranty, or further to its expiry, please contact our 
sales department to obtain authorisation for sending the 
instrument to our company.
The faulty product must be shipped to Ascon Tecnologic 
with a detailed description of the faults found, without any 
fees or charge for Ascon Tecnologic, except in the event of 
alternative agreements.

10.3 mAintenAnCe

This instrument does not requires periodical recalibration 
and it have no consumable parts so that no particular 
maintenance is required.
Sometimes it is advisable to clean the instrument.

1.  switCh the equipment oFF

  

(power supply, relay output, etc.).

2. 

Using a vacuum cleaner or a compressed air jet (max. 3 
kg/cm

2

) remove all deposits of dust and dirt which may 

be present on the case and on the internal circuits being 
careful not to damage the electronic components.

3. 

To clean external plastic or rubber parts use only a cloth 
moistened with:

• 

Ethyl Alcohol (pure or denatured) [C

2

H

5

OH] or

•  Isopropyl Alcohol (pure or denatured) [(CH

3

)

2

CHOH] 

or

•  Water (H

2

O).

4. 

Make sure that there are no loose terminals.

5. 

Before turning ON the instrument make sure it is perfectly 
dry.

6. 

Apply the power supply to the instrument.

Summary of Contents for KX6 Series

Page 1: ...r permanent installation for indoor use only in an electrical panel which encloses the rear housing exposed terminals and wiring on the back Select a mounting location having the following characteris...

Page 2: ...0 mA input wiring for passive transmitter using an external power supply _ _ 1 2 0 4 20 mA Passive transmitter _ External PWS Input impedance 50W 0 4 20 mA input wiring for active transmitter 0 4 20 m...

Page 3: ...4 NO 9 C NO Alarm 1 OP3 Alarm 2 OP4 Load AC 8 10 Load Contact rating 2 A 250 V cosj 1 1 A 250 V cosj 0 4 Operation 1 x 105 2 4 Serial Interface RS 485 D D GND 17 18 16 D D GND D D GND D D GND Interfac...

Page 4: ...0 023 in Weight 160 g max Power supply 100 240 VAC 15 10 of the nominal value Power consumption 5 VA max Insulation voltage 2300 V rms according to EN 61010 1 Display updating time 500 ms Sampling tim...

Page 5: ...s to take advantage of all instrument features The instrument have one complete parameter set indicated as Configuration parameter set or Configuration parameters The access to the configuration param...

Page 6: ...buttons set the value 581 3 Push button 4 The instrument turns ON all the LEDs for a few seconds then returns to the Standard display mode Notes 1 If the instrument does NOT TURN ON ALL the LEDs for...

Page 7: ...out 2 output while the values greater than zero activate the Open valve out 1 output 4 When ON OFF control is programmed and an out of range is detected the instrument performs the safety output valu...

Page 8: ...tion low alarm relative HidE Deviation high alarm relative LHdo Relative band alarm with alarm indication out of the band LHdi Relative band alarm with alarm indication inside the band Notes 1 The rel...

Page 9: ...1010 mBar but this value is out of range The reset can be made only by turning the instrument OFF removing the condition that generate the alarm and then turn the instrument ON again All band alarms u...

Page 10: ...to 0 the tempera ture must go down if not the SSR is in short circuit the valve is jammed and so on So the LBA should be generated LBA function is automatically enabled when the PID requires the maxi...

Page 11: ...7 EvoTune with manual start 8 EvoTune with automatic restart at all set point change 41 tunE Manual start of the auto tune Available Always Range oFF The instrument is not performing the auto tune on...

Page 12: ...start time Available When 39 cont PID or 39 cont 3Pt and 58 Pot Pot c Range oFF Function not used 0 01 7 59 hh mm inF Soft start always active Note The time calculation starts at Power ON and is inte...

Page 13: ...Note For other details see 61 SPLL parameter 63 SP Set Point 1 Available Always Range From 61 SPLL to 62 SPHL engineering units 64 SP 2 Set Point 2 Available When 60 nSP 2 Range From 61 SPLL to 62 SP...

Page 14: ...The first press puts the in strument in stand by mode while a second one puts the instrument in Auto mode SP1 2 SP SP2 selection Notes 1 When SP1 2 is used every press of the button longer than 1 sec...

Page 15: ...ence between AL P and AH P is equal to 10 Engineering Units 87 AL o Adjust Low Offset Available Always Range 300 300 engineering units 88 AH P Adjust High Point Available Always Range From AL P 10 to...

Page 16: ...L2 Pb A 7 Pb ti A 8 ti td A 9 td Aut r A 10 Aut r Now proceed as follows 1 Push the button for more than 3 seconds The upper display will show PASS while the middle display shows 0 2 By and buttons se...

Page 17: ...assword Notes 1 The factory default password for configuration parameters is 20 2 Operator and assistace level of Parameter modification are protected by a time out If no button is pressed for more th...

Page 18: ...always on display and no button is pressed for more than the programmed time out the display goes OFF and only 4 segments of the less significant digit are turned ON in sequence in order to show that...

Page 19: ...lectrical equipment for measurement control and laboratory use for this reason it could not be used as a safety equipment Whenever a failure or a malfunction of the control device may cause dangerous...

Page 20: ...to use it ti configure other instruments To transfer a complete instrument configuration to a PC or from a PC to an instrument To transfer a complete instrument configuration from a PC to an instrumen...

Page 21: ...Digital Input 2 function oFF 11 di A Digital Inputs Action DI2 only if configured 0 DI1 direct action DI2 direct action 1 DI1 reverse action DI2 direct action 2 DI1 direct action DI2 reverse action 3...

Page 22: ...n stand by mode 2 Alarm 1 enabled in out of range condition 3 Alarm 1 enabled in stand by mode and in out of range condition 0 AL2 group no Param Description Dec Point Values Default 27 AL2t Alarm 2 t...

Page 23: ...ower up and after a set point change 5 Evo tune with automatic restart at every power up 6 Evo tune with automatic start the first power up only 7 Evo tune with manual start 8 Evo tune with automatic...

Page 24: ...nction tunE Auto tune self tune enabling A single press longer than 1 se cond starts the auto tune oPLo Manual mode The first pressure puts the instrument in manual mode oPLo while a second one puts t...

Page 25: ...ted Master nonE Retransmission not used the instrument is a slave rSP The instrument becomes a Master and retransmits the operative set point PErc The instrument become a Master and it retransmits the...

Page 26: ...Ascon Tecnologic KX6 Line ENGINEERING MANUAL Vr 0 0 PAG 26...

Page 27: ...Ascon Tecnologic KX6 Line ENGINEERING MANUAL Vr 0 0 PAG 27...

Page 28: ...Ascon Tecnologic KX6 Line ENGINEERING MANUAL Vr 0 0 PAG 28...

Reviews: