10. For fill heads with limit switch, check
whether the release pin (8) is present
and functional.
NOTE
The release pin can stick or
harden due to the influence of chem-
icals. Therefore do not use the limit
switch with adhesive, hardening or crys-
tallizing chemicals.
11. In the case of conductive fill heads,
check whether a conductive dip tube
is installed and whether it is properly
grounded.
Follow the ATEX and OSHA instruc-
tions and regulations.
»
For further information, please refer
to the operating instructions of the dip
tube.
12. When using fill heads with an overfil-
ling sensor, check whether the sensor
in the housing is working properly. The
ventilation channel must be free of
any debris of the medium so that the
measuring field of the sensor is not
disturbed. A ventilation line must be
connected to the vent port so that no
medium can escape unhindered in the
event of overfilling.
Assembly/commissioning
5.3 Mounting the fill head
WARNING
Hazard from chemicals!
Chemicals can cause irritation and
chemical burns.
• Observe the proper Standard Operat-
ing Procedures (SOP) when handling
hazardous substances.
• Observe the safety data sheets (SDS)
of the chemicals used.
• Wear the necessary personal pro-
tective equipment (PPE) (suitable
protective clothing, protective gloves,
respirators and safety goggles / face
shield).
1. If a tamper-proof cap is fitted to the dip
tube closure of the container, remove
the blue seal on the original tam-
per-proof cap (1).