7. Check/test the chemical resistance of
the fill head for the chemical used.
»
On our website you will find a data-
base with some data on chemical
resistance, which can be used as a
guide.
Link:
https://asstroemungstechnik.de/
de/chembank
8. Check whether the fill head shows any
damage such as cracks or discoloring.
9. Use the first liters of product as flush-
ing chemistry to condition the fill head
and connections.
10. In the case of fill heads with overfilling
sensors, it must be checked whether
the medium to be filled is detected by
the sensor.
Assembly/commissioning