125
GUI Dialog
This diagnostic dialog can be accessed by the Maintenance – Imaje DIO pull down. The dialog has these
functions:
1.
Displays the active state of DSR from controller.
2.
Displays the active state of DTR from Imaje
3.
Allows toggle of DSR by clicking on the button.
4.
Displays the active state of DTOP.
5.
Allows toggle of DTOP by clicking on the button.
6.
Display the hardware Ready input state.
7.
Allow a click on button to tell the control to send an ENQ to the Imaje.
8.
Display result of ENQ when Control sends it, which could be:
a.
DSR/DTR handshake problem
b.
ACK received.
c.
NAK received.
d.
Loop back detected. (Data received is same as sent.)
e.
Timed out with no response.
9.
Display the Imaje state machine values for:
a.
Long Msg
b.
ENQ
c.
PO
10.
Click on Reset button to clear all Imaje states if one gets stuck at non-zero.
11.
Init a PO cycle which sends a brief burst of TACKY pulses to the Ink Jet. This can be used to
test the TACKY wiring.
Trouble shooting suggestions
When there is a problem with the ink jet on a CS327 it can be one or more of several problems. On a new
machine or one that has just been fitted with and ink jet interface problems mostly have to do with the
wiring. However, in testing the interface and wiring, if all the wiring checks out either the ARTOS
interface board or the Imaje industrial interface board may be bad. On older machines that have been
running the ink jet interface chances of a board failure does arise a bit more often and wiring issues have
to do more with loose or failed connections.