5
Module Status
Bit [0]
0: Module site is enabled.
1: Module site is disabled.
Bit [1]
0: Module is not present.
1: Module is present.
Bit [2]
0: Management power is disabled.
1: Management power is enabled.
Bit [3]
0: Management power is bad.
1: Management power is good.
Bit [4]
0: Payload power is disabled.
1: Payload power is enabled.
Bit [5]
0: Payload power is bad.
1: Payload power is good.
Bit [6]
0: IPMB-L buffer is not attached.
1: IPMB-L buffer is attached.
Bit [7]
0: IPMB-L buffer is not ready.
1: IPMB-L buffer is ready.
Table 8-47 Get Module State Command Description (continued)
Type Byte
Data
Field