Supported IPMI Commands
ATCA-7475 Installation and Use (6806800S38D)
239
9.4.8
Get Handle Switch Command
The Get Handle Switch command reads the state of the hot-swap handle of the IPMC.
Overriding of the handle switch state is allowed only if the IPMC operates in manual standalone
mode (for a description refer to
).
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Table 9-36 Set Hardware Address Command Description (continued)
Type Byte
Data
Field
Table 9-37 Get Handle Switch Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
5
Handle Switch Status
0x00: The handle switch is open.
0x01: The handle switch is closed.
0x02: The handle switch state is read from hardware.
Summary of Contents for ATCA-7475
Page 1: ...ATCA 7475 Installation and Use P N 6806800S38D May 2014 ...
Page 24: ...ATCA 7475 Installation and Use 6806800S38D About this Manual 24 About this Manual ...
Page 34: ...ATCA 7475 Installation and Use 6806800S38D Sicherheitshinweise 34 ...
Page 42: ...Introduction ATCA 7475 Installation and Use 6806800S38D 42 ...
Page 64: ...Hardware Preparation and Installation ATCA 7475 Installation and Use 6806800S38D 64 ...
Page 80: ...Controls Indicators and Connectors ATCA 7475 Installation and Use 6806800S38D 80 ...
Page 138: ...Functional Description ATCA 7475 Installation and Use 6806800S38D 138 ...
Page 250: ...Supported IPMI Commands ATCA 7475 Installation and Use 6806800S38D 250 ...
Page 268: ...FRU Information and Sensor Data Records ATCA 7475 Installation and Use 6806800S38D 268 ...
Page 281: ......