FRU Information and Sensor Data Records
ATCA-7475 Installation and Use (6806800S38D)
261
3
Version
change
Version
Change
0x2B
Sensor-specific
discrete
0x6F
0x7
Change type
0xFF
0x7: Software or F/W change
successful
Asrt
Auto
4
IPMB Physical
Physical
IPMB-0
0xF1
Sensor-specific
discrete
0x6F
0x0
0x1
0x2
0x3
[7:4] = Channel Number
[3:0] = Reserved
reading
0x0: IPMB-A disabled, IPMB-B
disabled
0x1: IPMB-A enabled, IPMB-B
disabled
0x2: IPMB-A disabled, IPMB-B
enabled
0x3: IPMB-A enabled, IPMB-B
enabled
Asrt
Auto
5
BMC
Watchdog
Watchdog 2
0x23
Sensor-specific
discrete
0x6F
0x0
0x1
0x2
0x3
0x8
See IPMI Spec
0xFF
0x0: Timer expired
0x1: Hard Reset
0x2: Power Down
0x3: Power Cycle
0x8: Timer Interrupt
Asrt
Auto
6
12.0V
Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass
Auto
7
3.3V
Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass
Auto
8
3.3V Mgmt
Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass
Auto
9
1.8V Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass
Auto
10
1.2V
Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass
Auto
11
1.0V
Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass
Auto
12
VCC CPU0
Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass
Auto
Table 10-7 Sensor Data Records (continued)
Sensor
Number
Sensor Name
Sensor Type
Event/Reading
Type
Event
Data
Byte 1
Event Data Byte 2
Event Data Byte 3
Event Threshold/Description
Assertion
Deassertion
Rearm
Asrt: Assertion Unr: Upper non-recoverable threshold Uc: Upper critical threshold Unc: Upper non-critical threshold
Deass: Deassertion Lnr: Lower non-recoverable threshold Lc: Lower critical threshold Lnc: Lower non-critical threshold
Summary of Contents for ATCA-7475
Page 1: ...ATCA 7475 Installation and Use P N 6806800S38D May 2014 ...
Page 24: ...ATCA 7475 Installation and Use 6806800S38D About this Manual 24 About this Manual ...
Page 34: ...ATCA 7475 Installation and Use 6806800S38D Sicherheitshinweise 34 ...
Page 42: ...Introduction ATCA 7475 Installation and Use 6806800S38D 42 ...
Page 64: ...Hardware Preparation and Installation ATCA 7475 Installation and Use 6806800S38D 64 ...
Page 80: ...Controls Indicators and Connectors ATCA 7475 Installation and Use 6806800S38D 80 ...
Page 138: ...Functional Description ATCA 7475 Installation and Use 6806800S38D 138 ...
Page 250: ...Supported IPMI Commands ATCA 7475 Installation and Use 6806800S38D 250 ...
Page 268: ...FRU Information and Sensor Data Records ATCA 7475 Installation and Use 6806800S38D 268 ...
Page 281: ......